Confidential
Chapter 3
Connecting Cables
MT3204 Series Installation Manual v1.0
80
Copyright © 2018, All Rights Reserved.
Category
Description
MMU
M6 × L12 SEMS (Hex.+)/2 EA
Recommended
Torque Value
M6 SEMS
43 lbf·in
Working Tools
Cable Cutter
Wire Stripper
Crimping tool
Heating Gun
Nipper
Screw Driver (‘+’, Number 3)
Torque Driver (20 to 90 lbf·in.)
Screw Driver Bit (‘+’, Number 3)
For the pressure terminals of the cable, the UL listed products or equivalent must
be used.
For example, Manufacturer-Panduit
- MMU: 6 AWG Pressure Terminal (LCD6-14A-L)
It is recommended to apply antioxidant (ex.grease) to prevent oxidation before
connecting the pressure terminal.
1
Install the ground cable from the MGB to the MMU ground terminal, as
shown in figure below:
Figure 72.
Connecting Ground Cable (1)
2
Remove the fastener (M6 SEMS) from the MMU ground terminal.
3
Assemble a pressure terminal and a heat shrink tube at the end of the MMU
ground cable.
4
Align the pressure terminal to the mounting hole of the MMU ground
terminal.
5
Firmly fix the pressure terminal onto the MMU ground terminal using
MGB
Ground Cable
[Bottom View]