Safety precautions

Carefully follow the precautions listed as below because they are essential to guarantee the safety of SAMSUNG product.

WARNING

•  Always disconnect a power supply of Air-Water Heat Pump before servicing it or accessing 

components inside the unit.

•  Verify that installation and testing operations shall be performed by qualified personnel.
•  To prevent serious damage on the system and injuries to users, precautions and other 

notices shall be observed.

Warning

f

f

Carefully read the contents of this manual before installing the control kit and store the manual in a safe place in order to 
be able to use it as reference after installation.

f

f

For maximum safety, installers should always carefully read the following warnings.

f

f

Store the manual in a safe location and remember to hand it over to the new owner if the kit is sold or transferred.

f

f

The kit is compliant with the requirements of the Low Voltage Directive (72/23/EEC), the EMC Directive (89/336/EEC) and 
the Directive on pressurized equipment (97/23/EEC).

f

f

The manufacturer shall not be responsible for damage originating from unauthorized changes or the improper 
connection of electric and hydraulic lines. Failure to comply with these instructions or to comply with the requirements 
set forth in the “Operating limits” table, included in the manual, shall immediately invalidate the warranty.

f

f

Do not use the units if you see some damages on the units and recognize something bad such as loud noisy, smell of 
burning.

f

f

In order to prevent electric shocks, fires or injuries, always stop the unit, disable the protection switch and contact 
SAMSUNG’s technical support if the unit produces smoke, if the power cable is hot or damaged or if the unit is very noisy.

f

f

Always remember to inspect the unit, electric connections, and protections regularly. These operations shall be 
performed by qualified personnel only.

f

f

The unit contains various electric parts, which should be kept out of the reach of children.

f

f

Do not attempt to repair, move, alter or reinstall the unit by unauthorized personnel, these operations may cause product 
damage, electric shocks and fires.

f

f

Do not place containers with liquids or other objects on the unit. 

f

f

All the materials used for the manufacture and packaging of the air to water heat pump are recyclable.

f

f

The packing materials must be disposed of in accordance with local regulations.

f

f

Wear protective gloves to unpack, move, install, and service the unit to avoid your hands being injured by the edge of the 
parts.

f

f

Do not touch the internal parts while running the units. 

f

f

Inspect the product shipped and check if damaged during transport. If the product has some damages, 

f

f

DO NOT INSTALL and immediately discuss about the damages with the carrier or retailer (if the installer or the authorized 
technician has collected the material from the retailer.)

f

f

Our units shall be installed in compliance with the spaces described in the installation manual, to ensure accessibility 
from both sides and allow repairs or maintenance operations to be carried out. If the units installed without complying 
with procedures described in manual, additional expenses can be asked because special harnesses, ladders, scaffolding 
or any other elevation system for repair service will NOT be considered part of the warranty and will be charged to the 
end customer.

f

f

When service works required, make sure to disconnect the power supply at least 1 minute to prevent electric shocks.

 - Always check the voltage at the terminals of main PCB before trying to touch.

f

f

Use electric wires which manual designated. Connections between wires and terminals shall be assembled without any 
tension. If the assembly works is not implemented well, it can lead to have product damages and fires.

f

f

After wiring works, terminal block cover shall be fixed firmly. Without cover, it can cause to have product damage and fire.

Contents

Safety precautions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   3
Product specifications    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   4
Main components   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   4
Installing the unit  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   5
Wiring works    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   8
Setting option switches and function of keys  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   23
Test operation   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   27
Before running the system  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   29
Troubleshooting  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   30
Error codes   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   31

Summary of Contents for MIM-E03A

Page 1: ...iant with RoHS MIM E03 SAMSUNG CONTROL UNIT installation manual imagine the possibilities ThankyouforpurchasingthisSamsungproduct To receive more complete service please register your product at www samsung com register E S F I P D DB98 00000A 1 ...

Page 2: ...ach of children f f Do not attempt to repair move alter or reinstall the unit by unauthorized personnel these operations may cause product damage electric shocks and fires f f Do not place containers with liquids or other objects on the unit f f All the materials used for the manufacture and packaging of the air to water heat pump are recyclable f f The packing materials must be disposed of in acc...

Page 3: ...s are stored f f Choose a specific wall which can withstand the weight of unit and an outside force Mounting the unit Procedure Remark 1 Remove 2 bolts from the unit Bolt 2 Open the top cover and install 4 screws on the wall 3 Close the top cover and install 2 bolts again into the unit Product specifications Item Description MIM E03A Wired remote controller Temperature sensor Thermistor 1EA Remote...

Page 4: ...te controller cable through the upper portion Remote controller cable Wood screw B 4 Connect the remote controller cable to the terminal block TB6 No polarity ToTB62 No 5 and 6 on the FTC unit Installing the unit Installing the remote controller Connecting the wired remote controller cable to FTC f f Connect the wired remote controller cable to 5 and 6 on the terminal block TB62 on the FTC control...

Page 5: ...use Heater Water Pump Valve Wired RMC 1Ø 220 240V 50Hz 1 5 3 L 10m 10 2 5 3 10m L 10 Use Booster Heater 3kw 4 0 3 L 10m 30 6 0 3 10m L 30 Connecting the communication wire f f Connect outdoor unit s F1 F2 with control kit s F1 F2 inTB C by 2 core cable Outdoor Unit at Control Plate Control Kit Wiring works Overall schematics Flow S W Outdoor Unit Temp Sensor Solar Main Power Relay Pump Booster Hea...

Page 6: ... 230V MAX 20A Wiring works Communication with wired remote controller Wired Remote Controller Connecting the wired remote controller 1 Connect V1 V2 F3 F4 of control kit with V1 V2 F3 F4 of wired remote controller f f You can connect maximum 2 set of wired remote controller f f In case of 2 sets for wired remote controller installation master slave settings shall be implemented Temperature sensor ...

Page 7: ...nnection load Signal for turning Backup Boiler on Driving for Relay or Magnetic Contactor Output AC 230V MAX 0 5A Wiring works Backup heater Magnetic ContactorWire Connecting magnetic contactor for backup heater Not Directly Connect Heater 1 Connect Magnetic contactor wire with pin 1 2 3 inTB B f f If control kit turns on the 1st step of backup heater pin 1 pin 2 will output AC230V f f If control ...

Page 8: ... line 10 Output turning on Power Normal Closed L line Connection load Direct connect 2way valves under 0 5A Output AC 230V MAX 0 5A 120W Wiring works Water pump Water Pump Connecting water pump 1 Directly connect water circulation pump with pin 5 6 inTB B f f If control kit orders turning water pump on pin 5 pin 6 will output AC230V Maximum Power This port can supply power for small medium sized w...

Page 9: ...Condition for operation NOT Define Wiring works Example of valve connection f f 2 pole L1 N type L1 port ofValve is connected to 10 N port ofValve is connected to 7 If L1 N ports ofValve get power water can NOT flow to DHW tank If L1 N ports ofValve don t get power water can flow to DHW tank f f 3 pole L L1 N type L port ofValve is connected to 8 L1 port ofValve is connected to 10 N port ofValve i...

Page 10: ...120W Condition for operation NOT Define Wiring works Example of valve connection f f 2 pole L1 N type L1 port ofValve is connected to 13 N port ofValve is connected to 11 If L1 N ports ofValve get power water can flow to Zone1 If L1 N ports ofValve don t get power water can NOT flow to Zone1 f f 3 pole L L1 N type L port ofValve is connected to 12 L1 port ofValve is connected to 13 N port ofValve ...

Page 11: ...in 22 detects L line the valve for Zone1 will open outdoor unit will operate for heating mode Pin 23 detects L line the valve for Zone2 will open outdoor unit will operate for cooling mode Pin 24 detects L line the valve for Zone2 will open outdoor unit will operate for heating mode Wiring works Example of valve connection f f 2 pole L1 N type L1 port ofValve is connected to 17 N port ofValve is c...

Page 12: ...non detection For Commissioning Emergency S W 6 Normal operation Emergency S W 7 No use No use S W 8 No use No use Wiring works Solar Pump Solar Panel Connecting solar pump 1 Connect Solar pump power line with pin 25 26 inTB B f f If pin 25 26 get AC230V Control Kit will aware Solar Panel supply heat to DHW tank Maximum Consumption Power Each port use under 10mA NOTE Specification table Part Speci...

Page 13: ...ank 0 1 Room Zone 1 72 1 Room 0 1 Zone 2 73 1 Room 0 1 Setting option switches and function of keys Field setting mode Field SettingValue FSV Table Code 10 Upper and lower temperature limits of each operation mode of wired remote controller Heating Water Out Room Cooling Water Out Room DHW Tank Code 20 Water law design and external room thermostat Heating 2WL s for floor FCU Cooling 2WL s for floo...

Page 14: ...der If no input additionally for 5 sec it will be restored to previous condition Setting option switches and function of keys Code 40 User s options for heating devices including internal backup heater and external boiler 401 Space DHW heating priority and control variables 402 Backup Booster heater priority and control variables 403 Additional backup boiler operating variables Code 50 User s opti...

Page 15: ...ode shall be possible regardless of outdoor communication error It is available after change DIP 5 and DIP 6 into ON and re set mode Enable disable modes allowed for heating and how water mode Heater mode will be available after each ON mode and disable mode can be ended by each OFF input available for Simultaneous Operation Depending on the condition of heater or tank un installation using heater...

Page 16: ...page carefully and implement visual inspections of the whole system Possible causes Actions Heating or cooling performance are not good Check the temperature adjustment in the controller Check if the water is filled in the system fully Check the water flow rate Loud noise from water pump Check air purge valve Make it open and close Check if the water is filled in the system fully Check if strainer...

Reviews: