22
23
EN
G
LIS
H
Setting option switches and function of keys
DIP switch setting
S/W
OFF (Default)
ON
S/W #1
Heating and cooling
Heating only
S/W #3
Target temp. : Water outlet temp.
Target temp. : Indoor temp.
S/W #3
Air sensor in remote controller
External air sensor
S/W #4
Master Remote controller
Slave Remote controller
S/W #5
Error detection when outdoor communication is
broken
Error non-detection , For Commissioning /
Emergency
S/W #6
Normal operation
Emergency
S/W #7
No use
No use
S/W #8
No use
No use
Wiring works
Solar Pump
Solar Panel
Connecting solar pump
1. Connect ‘Solar pump power line’ with ‘pin #25, 26’ in TB-B.
f
f
If pin#25, 26 get AC230V, Control Kit will aware Solar Panel supply heat to DHW tank.)
Maximum Consumption Power
Each port use under 10mA
NOTE
Specification table
Part
Specification
Connection pin
#25 : Output Power N
#26 : Detecting Power L
Connection load
Direct connect from solar pump (AC230V)
Output
AC 230V (MAX 10mA)
Condition for operation
(NOT Define)