SAMSUNG Confidential
MODEL
LSC460HJ03
Doc. No
Page
35 / 42
2. The guide for the mechanical design
2.1 The panel guide
(a) It is recommended to avoid the following cases since the light leakage can be caused by the
pressure of the guiding structure.
When the guiding part is made of plastic resin, the gap between the panel and the guiding structure
should be considered when you design. The shrinkage under the situation which the temperatures
change causes the light leakage. For your reference, it is recommended to have a total gap between
the panel and the guide structure as below (When the resin is composed of the PC and the 15% of
G/F.)
t
32”
40”
46”
55”
Total Gap
Right & Left
0.9
0.9
1.0
1.1
Top & Bottom
0.6
0.7
0.8
0.9
It is recommended to follow the dimension and the shape of the guiding structure stated as below
since the distortion of guiding parts can cause the light leakage