![Samsung iPOLiS SNP-3120 User Manual Download Page 19](http://html.mh-extra.com/html/samsung/ipolis-snp-3120/ipolis-snp-3120_user-manual_353826019.webp)
English
_19
●
OVER
VIEW
Power, Video & Communication Signal Connection
No.
Name
Usage
1
VIDEO
Video Output
2
GND
Ground
3
485+
Controller Data Line
4
485-
Controller Data Line
5
FG
Field Ground
6
AC
AC 24V
7
AC
AC 24V
M
The provided BNC cable’s blue line is Video Output, while the black line is the Ground.
Power supply adaptor (AC) has no polarities.
J
The maximum power capacity of the built-in relay is 30V DC/2A, 125V AC/0.5A, and 250V
AC/0.25A.
Connecting the power connector and GND incorrectly to the NC/NO and COM ports may cause a
short circuit and fi re, damaging the camera.
When connecting the camera to an external over-rated product, use a separate relay device to
ensure proper operation.
To prevent possible inflow of lightning while in test monitoring, perform the test with the FG
terminal grounded.