LED R&D Lab(VD)
9
◆
Heat dissipation guide
Installation condition
- Conditions for using SAMSUNG WALL MOUNT
- Solar direct sunlight conditions cannot be installed (including glass window passage conditions)
- It is recommended to use room temperature below 25°C
- Effect of Cold/Hot Air Conditioning System
- When cold / hot air is the same air conditioning system,
∙
Be careful not to let the warm air touch the product.
- Outside temperature measurement position
Measured at a distance of 300mm from the center of the product
Air vent aperture ratio
-
use mesh type air vent
-
If the aperture ratio is not 100%, the separation distance =
Minimum distance
aperture ratio(%) / 100
-
aperture ratio (%) =
𝑐𝑐 𝑋𝑋 𝑑𝑑 𝑋𝑋 𝑁𝑁𝑁𝑁
.
𝑁𝑁𝑜𝑜 𝑣𝑣𝑣𝑣𝑣𝑣𝑣𝑣 ℎ𝑁𝑁𝑜𝑜𝑣𝑣
𝐴𝐴 𝑋𝑋 𝐵𝐵
※ It is written based on Full white, back light 7
Video, created based on back light 10
A
B
d
c
w
all
Outside
temperature
measurement
position
300mm
1. Product and installation information