5. Electrical Connections
As shown in the [Table 5-1], the input / output power cables correspond to the AC/ DC input
/ output specifications for this system.
Recommended cables for the 3.6 kWh All in One
Area
Insulation
Color code
Grid (L,N)
6mm
2
600V or more
Black
PE
6mm
2
600V or more
Green with yellow lines
PV (+), (-)
6mm
2
700V or more
Black
Object
Part List
A
AC reactor
INVERTER
B
DC relay
INVERTER
C
BDC side connector (BATT-A)
INVERTER
D
Battery side connector (BATT-B)
BATTERY
E
FAN2
INVERTER
F
PV1 reactor
INVERTER
G
PV2 reactor
INVERTER
H
BDC reactor
INVERTER
I
FAN1
INVERTER
BD 1
Board1 (PN. SJ92-01425A)
INVERTER
BD 2
Board2 (PN. SJ92-01467C)
INVERTER
BD 3
Board3 (PN. SJ92-01434A)
INVERTER
BD 4
Board4 (PN. SJ92-01426A)
INVERTER
BD 5
Board5 (PN. SJ92-01427A)
INVERTER
BD 6
Board6 (PN. SJ92-01424D)
INVERTER
BD_BM
Board battery management (PN. SJ92-01405A)
BATTERY
BD_CAP
Board CAP (PN. SJ92-01428A)
INVERTER
BT_B
Battery Tray bottom view
BATTERY
BT_T
Battery Tray top view
BATTERY
CP
Communication part
INVERTER
E_I/O
Electrical I/O part
INVERTER
[Table 5-1: Component Description]
Australia (Eng.) 05/2015. Rev1.1
23