Installation
English
30
4-wire system
F
A B
C L2
L1
D
E
A.
External ground connector
B.
Neutral grounding wire (white)
C.
Center silver-colored terminal block
screw
D.
Neutral wire (white or center wire)
E.
¾” (1.9 cm) UL-listed strain relief
F.
Neutral wire (white or center wire)
1.
Remove the external ground connector’s screw and
connect the ground wire (green or unwrapped) of the
power cable to the screw.
CAUTION
-
To connect the ground wire to the neutral position
without through contact A (cabinet ground),
contact a technician. This is not user serviceable.
-
Ring-type terminals are recommended. If using
strap terminals, make sure they are tightened.
2.
Loosen or remove the screws from the center
terminal block.
3.
Connect the neutral wire (white or center wire)
and ground wire (white) to the center screw of the
terminal block. Tighten the screw.
4.
Connect the other wires to the outer terminal block
screws. Tighten the screws.
5.
Tighten the strain relief screws.
6.
Insert the tab of the terminal block cover into the
rear slot of the dryer. Secure the cover with a hold-
down screw.
CAUTION
Connect the power cord and check L1/L2/N voltage. If the voltage is low, it may not heat properly. Review
the “
” section on page
if needed.
WARNING
• All U.S. models are designed for a 3-wire system connection. The dryer frame is grounded to the
neutral conductor at the terminal block. A 4-wire system connection is required for new or remodeled
construction, mobile homes, or if local codes do not permit grounding through neutral. If you use the
4-wire system, you cannot ground the dryer frame to the neutral conductor at the terminal block.
• Remove the terminal block cover plate. Insert the power cord with a UL-listed strain relief through the
hole provided in the cabinet near the terminal block.
• A strain relief must be used. Do not loosen the nuts already installed on the terminal block. Be sure
they are tight. Use a 3/8” (1 cm) deep well socket.
• Since january 1, 1996, the national electric code requires that new wiring (not existing) utilize a 4-wire
connection to this dryer.
Untitled-1 30
2023-08-10( ) 12:26:37
Summary of Contents for DVE51CG8005 Series
Page 1: ...Dryer Usermanual DVE G 51CG8000 DVE51CG8005 Untitled 1 1 2023 08 10 12 26 32 ...
Page 61: ...Memo Untitled 1 61 2023 08 10 12 26 44 ...
Page 62: ...Memo Untitled 1 62 2023 08 10 12 26 44 ...
Page 63: ...Memo Untitled 1 63 2023 08 10 12 26 45 ...
Page 65: ...Sèche linge Manueld utilisation DVE G 51CG8000 DVE51CG8005 Untitled 3 1 2023 08 10 12 30 09 ...
Page 126: ...Mémo Untitled 3 62 2023 08 10 12 30 22 ...
Page 127: ...Mémo Untitled 3 63 2023 08 10 12 30 22 ...
Page 129: ...Secadora Manualdelusuario DVE G 51CG8000 DVE51CG8005 Untitled 2 1 2023 08 10 12 28 31 ...