ElEctrIcal connEctIonS
Before operating or testing, follow all grounding instructions in the grounding section.
An individual branch (or separate) circuit serving only your dryer is recommended. DO NOT USE AN
EXTENSION CORD.
Gas models – U.S. and Canada
A 120 volt, 60 Hz AC approved electrical service, with a 15-ampere fuse or circuit breaker is
required.
Electric models – U.S. only
Most U.S. dryers require a 120 / 240 volt, 60 Hz AC approved electrical service. Some require
120 / 208 volt, 60 Hz approved electrical service. The electric service requirements can be found
on the data label located behind the door. A 30-ampere fuse or circuit breaker on both sides of
the line is required.
•
If a power cord is used, the cord should be plugged into a 30-ampere receptacle.
•
The power cord is NOT provided with U.S. electric model dryers.
Risk of Electric Shock
When local codes allow, the dryer electrical supply may be connected by means of a new
power supply cord kit, marked for use with a dryer, that is U.L. listed and rated at a minimum of
120/240 volts, 30-ampere with three No. 10 copper wire conductors terminated with closed loop
terminals, open-end spade lugs with turned up ends, or with tinned leads.
•
Do not reuse a power supply cord from an old dryer. The power cord electric supply wiring
must be supported at the dryer cabinet by a suitable UL-listed strain relief.
•
Grounding through the neutral conductor is prohibited for (1) new branch-circuit installations,
(2) mobile homes, (3) recreational vehicles, and (4) areas where local codes prohibit
grounding through the neutral conductor. (Use a 4-prong plug for a 4 wire receptacle, NEMA
type 14-30R.)
Electric models – Canada Only
•
A 120 / 240 volt, 60 Hz AC approved electrical service fused through a 30-ampere fuse or
circuit breaker on both sides of the line is required.
•
All Canadian models are shipped with the power cord attached. The power cord should be
plugged into a 30-ampere receptacle.
It is not permissible to convert a dryer in Canada to 208 volts.
installing your dryer
Warning
DV9100HA-DC68-03170K-12-EN.indd 14
2018/11/19 14:14:32
Summary of Contents for DV56H9100EV
Page 41: ...memo DV9100HA DC68 03170K 12 EN indd 41 2018 11 19 14 14 38 ...
Page 42: ...memo DV9100HA DC68 03170K 12 EN indd 42 2018 11 19 14 14 38 ...
Page 43: ...memo DV9100HA DC68 03170K 12 EN indd 43 2018 11 19 14 14 38 ...
Page 85: ...mémo DV9100HA DC68 03170K 12 CFR indd 41 2018 11 19 14 38 40 ...
Page 86: ...mémo DV9100HA DC68 03170K 12 CFR indd 42 2018 11 19 14 38 40 ...
Page 87: ...mémo DV9100HA DC68 03170K 12 CFR indd 43 2018 11 19 14 38 40 ...
Page 129: ...comentarios DV9100HA DC68 03170K 12 MES indd 41 2018 11 19 14 47 10 ...
Page 130: ...comentarios DV9100HA DC68 03170K 12 MES indd 42 2018 11 19 14 47 10 ...
Page 131: ...comentarios DV9100HA DC68 03170K 12 MES indd 43 2018 11 19 14 47 10 ...