3-WIRE SYSTEM CONNECTIONS
1.
Loosen or remove center terminal block screw.
2.
Connect neutral wire (white or center wire) of the power cord to the center, silver-colored
terminal screw of the terminal block. Tighten screw.
3.
Connect the other wires to outer terminal block screws. Tighten screws.
4.
Tighten strain relief screws.
5.
Insert tab of terminal block cover into your dryer’s rear panel slot.
Secure cover with hold-down screw.
• External ground connector
• Neutral grounding wire (green/yellow)
• Center silver-colored terminal block screw
• Neutral wire (white or center wire)
• 3/4” (1.9 cm) UL-listed strain relief
WARNING
: If converting from a 4-wire electrical system to a 3-wire, the ground strap must be
reconnected to the terminal block support to ground the dryer frame to the neutral conductor.
4-WIRE SYSTEM CONNECTIONS
1.
Remove center terminal block screw.
2.
Connect ground wire (green or unwrapped) of power cord to external ground conductor screw.
3.
Connect neutral wire (white or center wire) of power cord and appliance ground wire (green
with yellow stripes) under central screw of the terminal block.
4. Connect the other wires to outer terminal block screws. Tighten screws.
5.
Tighten strain relief screws.
6.
Insert tab of terminal block cover into your dryer’s rear panel slot.
Secure cover with hold-down screw.
• External ground connector
• Green or bare copper wire of power cord
• 3/4 in. (1.9 cm) UL-listed strain relief
• Center silver-colored terminal block screw
• Grounding wire (green/yellow)
• Neutral wire (white or center wire)
6.
With a level, check your dryer and make necessary adjustments to the leveling legs.
7.
At this time, make sure all gas connections (on gas models), exhaust and electrical connections are
complete. Plug in your dryer, and check operation by using the checklist below.
8.
(GAS MODELS ONLY)
The burner may not ignite initially due to air in the gas line. Allowing your dryer to operate on a heat
setting will purge the line. If the gas does not ignite within 5 minutes, turn your dryer off and wait
5 minutes. Be sure the gas supply to your dryer has been turned on. In order to confi rm gas ignition,
check the exhaust for heat.
FINAL INSTALLATION CHECKLIST
□
Dryer is plugged into electrical outlet and properly grounded.
□
Exhaust ductwork is hooked up and joints taped.
□
Plastic fl exible duct is NOT used.
□
Use rigid or stiff-walled fl exible metal vent material.
□
Dryer is level with all legs fi rmly on the fl oor.
□
Gas models – gas is turned on with no gas leaks.
□
Start your dryer to confi rm that it runs, heats, and shuts off.
Summary of Contents for DV306LEW/XAA
Page 22: ...2 3 5061 RYHUYLHZ RI WKH GU HU ...
Page 25: ...2 6 Memo ...
Page 31: ...3 6 6071 GHVLJQDWLRQ RI PDLQ FRPSRQHQWV 607041 Khdwhu ...
Page 33: ...3 8 ڐ ڐ ډ ۇڼھۄۉڼۃھۀڨ ۉۊۄێۉۀۈۄڟ ΤΡΖΔ ρ ρ ρ ρ ρ ρ ...
Page 43: ...5 6 8061 UHDVVHPEO Reassembly procedures are in the reverse order of dissasembly procedures ...
Page 49: ...6 6 Memo ...
Page 64: ...9 1 1 EORFN GLDJUDP 041 EORFN GLDJUDP ...
Page 65: ...9 2 Memo ...
Page 66: ...10 1 431 ZLULQJ GLDJUDP 43041 ZLULQJ GLDJUDP ...
Page 67: ...10 2 Memo ...
Page 68: ...11 1 441 SFE GLDJUDP 4404 PDLQ SFE OD RXW ...
Page 69: ...11 2 4405 VXE SFE OD RXW ...
Page 71: ...12 2 This Document can not be used without Samsung s authorization 4505 VXE SFE ...
Page 72: ...13 1 461 FLUFXLW GHVFULSWLRQV 46041 RYHUDOO V VWHP ...
Page 79: ...13 8 Memo ...
Page 80: ...14 1 471 UHIHUHQFH LQIRUPDWLRQ 47041 PRGHO QDPH ...