GAS REQUIREMENTS
Use only natural or LP (liquid propane) gases.
THE INSTALLATION MUST CONFORM WITH LOCAL CODES, OR IN THE ABSENCE OF LOCAL
CODES, WITH THE NATIONAL FUEL GAS CODE ANSI/Z223.1, LATEST REVISION (FOR THE UNITED
STATES), OR WITH THE CAN/CGA-B149 INSTALLATION CODES (FOR CANADA).
Gas dryers are equipped with a burner vent for use with natural gas. If you plan to use your dryer with LP
(liquid propane) gas, it must be converted for safe and proper performance by a qualifi ed service technician.
A 1/2” (1.27 cm) gas supply line is recommended and must be reduced to connect to the 3/8” (1 cm) gas line
on your dryer. The National Fuel Gas Code requires that an accessible, approved manual gas shut-off valve
be installed within 6’ of your dryer.
Gas dryers installed in residential garages must be raised 18 inches (46 cm) above the fl oor.
Additionally, a 1/8” (0.3 cm) N.P.T. (National Pipe Thread) plugged tapping, accessible for test gauge
connection, must be installed immediately upstream of your dryer’s gas supply connection.
Your dryer must be disconnected from the gas supply pipe system during any pressure testing of the
system.
DO NOT
reuse old fl exible metal gas lines. Flexible gas lines must be design certifi ed by the American Gas
Association (CGA in Canada).
NOTE:
• Any pipe joint compound used must be resistant to the action of any liquefi ed petroleum gas.
• As a courtesy, most local gas utilities will inspect a gas appliance installation.
GAS IGNITION
– Your dryer uses an automatic ignition system to ignite the burner.
There is no constant burning pilot.
COMMONWEALTH OF MASSACHUSETTS INSTALLATION INSTRUCTIONS
Your dryer must be installed by a licensed plumber or gas fi tter. A “T” handle manual gas valve must be
installed in the gas supply line to your dryer. If a fl exible gas connector is used to install your dryer, the
connector must have a maximum length of 3’ (36”).
WARNING
–
Gas leaks may occur in your system, creating a dangerous situation.
Gas leaks may not be detected by smell alone.
Gas suppliers recommend you purchase and install a UL-approved gas detector.
Install and use in accordance with manufacturer’s instructions.
Summary of Contents for DV306LEW/XAA
Page 22: ...2 3 5061 RYHUYLHZ RI WKH GU HU ...
Page 25: ...2 6 Memo ...
Page 31: ...3 6 6071 GHVLJQDWLRQ RI PDLQ FRPSRQHQWV 607041 Khdwhu ...
Page 33: ...3 8 ڐ ڐ ډ ۇڼھۄۉڼۃھۀڨ ۉۊۄێۉۀۈۄڟ ΤΡΖΔ ρ ρ ρ ρ ρ ρ ...
Page 43: ...5 6 8061 UHDVVHPEO Reassembly procedures are in the reverse order of dissasembly procedures ...
Page 49: ...6 6 Memo ...
Page 64: ...9 1 1 EORFN GLDJUDP 041 EORFN GLDJUDP ...
Page 65: ...9 2 Memo ...
Page 66: ...10 1 431 ZLULQJ GLDJUDP 43041 ZLULQJ GLDJUDP ...
Page 67: ...10 2 Memo ...
Page 68: ...11 1 441 SFE GLDJUDP 4404 PDLQ SFE OD RXW ...
Page 69: ...11 2 4405 VXE SFE OD RXW ...
Page 71: ...12 2 This Document can not be used without Samsung s authorization 4505 VXE SFE ...
Page 72: ...13 1 461 FLUFXLW GHVFULSWLRQV 46041 RYHUDOO V VWHP ...
Page 79: ...13 8 Memo ...
Page 80: ...14 1 471 UHIHUHQFH LQIRUPDWLRQ 47041 PRGHO QDPH ...