Troubleshooting _ 31
The clothes are not dried.
The problem is in the PCB
assembly. Please replace it.
Install the vent so that it is not blocked to the outside.
(Check the exhaust hole)
Clean the filter.
(Check if there are any alien particles in
the filter)
Connect the terminal block properly.
(Check the connection of Live 2, Neutral,
Live 1)
Neutral
Earth
L2
L1
Connect the touch sensor.
(Check the PCB and touch sensor)
Is the vent properly
installed?
Yes
No
Check the Safety, Hi-Limit thermostat.
(Check the cause of safety being off)
Did you clean the
filter before drying?
Yes
No
Is the terminal block
connection normal?
Yes
No
Is the touch sensor
normal?
Yes
No
Is the Tamp. Sensor
normal?
Yes
No
Is the safety, Hi-limit
thermostat normal?
Yes
No
Is the heater normal?
Yes
No
Replace the thermistor
(Check the connection between the
PCB and termistor and check for any
disconnection)
Replace the heater
(Remove the power and check whether the
heater coil has a resistance of about 10Ω)