3. Disassembly and Reassembly
Part
Photo
Description
Fan Motor
4. Remove the cover fan by rotating it
counterclockwise.
Use a jig. If you have no jig, use a tool such as a
pair of long nose pliers. Remove it carefully so that
the part is not damaged.
5. Remove the two (2) screws holding the cover fan in
place.
6. Hold and remove both the case vent assy and the
duct condenser assy together which are located at
the front of the tub front.
Caution
Be careful while removing them as the duct
condenser assy is touching the bracket door link and
the cushion duct L/R.
7. Remove the fan motor from the case vent assy.
It is connected with two (2) screws and the fan vent
is inserted into the shaft of the fan motor. Remove
the screws first and carefully pull out the fan motor.
8. Remove the duct condenser from the case vent
assy. Remove the three (3) screws.
9. Remove the case vent assy, fan motor, fan vent,
duct condenser, and seal vent.
Summary of Contents for DMR78AHS/XAC
Page 14: ...2 6 2 Features and Specifications Memo ...
Page 38: ...3 24 3 Disassembly and Reassembly Memo ...
Page 59: ...4 Troubleshooting 4 21 Memo ...
Page 73: ...5 14 5 Exploded Views and Parts List 5 7 MAIN DMR57 0 1 D049 Z019 P143 ...
Page 85: ...5 26 5 Exploded Views and Parts List ...
Page 95: ...6 10 6 PCB Diagram Memo ...
Page 103: ...8 5 8 Schematic Diagram Memo ...
Page 104: ...9 1 9 Reference 9 Reference 9 1 Model Number Naming Rules 8 2008 A ALL ...