4. Troubleshooting
4-16
Error type
Error mode
Checking Method
Corrective actions
The nozzle does not
inject water.
None
1. Check the connections for the Circulation Motor
connector.
- Reconnect the Circulation Motor connector.
2. Check the connections for the Startup Condenser
connector of the Circulation Motor.
- Reconnect the Startup Condenser connector of the Circulation Motor.
3. Check the resistance for the Circulation Motor coil.
(Remove the connector before measuring.)
Normal: Approx. 16.5 Ω
➢
- Faulty: Replace the Circulation Motor.
All manuals and user guides at all-guides.com
Summary of Contents for DMR78 series
Page 14: ...2 6 2 Features and Specifications Memo All manuals and user guides at all guides com...
Page 38: ...3 24 3 Disassembly and Reassembly Memo All manuals and user guides at all guides com...
Page 59: ...4 Troubleshooting 4 21 Memo All manuals and user guides at all guides com...
Page 85: ...5 26 5 Exploded Views and Parts List All manuals and user guides at all guides com...
Page 95: ...6 10 6 PCB Diagram Memo All manuals and user guides at all guides com...
Page 103: ...8 5 8 Schematic Diagram Memo All manuals and user guides at all guides com...