3-15
3. Disassembly and Reassembly
Part
Photo
Description
Dispenser
1. Open the door completely.
Remove the twelve (12) screws holding the tub front,
fame front, and panel front in place.
Caution
Before removing the screws, place a cushioned mat
on the floor to prevent the handle and frame front
from being scratched. After removing them, make
sure to hold the tub front with your hand while you
are working as the tub may close and harm you.
Caution
Do not place the removed screws on the tub front.
They may fall into the sump assy.
2. Remove the fan motor connector.
3. Remove the four (4) connectors on both sides of the
Dispenser.
Caution
The connectors are of the locking type and are
hard to remove. Be careful not to break them when
removing them.
4. Remove the six (6) screws holding the tub front and
the two (2) racket dispensers in place.
5. The dispenser is fixed to the tub front with a hook.
Use a flat screwdriver to remove it from the tub front.
Caution
Be careful as the tub front is sharp.
All manuals and user guides at all-guides.com
Summary of Contents for DMR78 series
Page 14: ...2 6 2 Features and Specifications Memo All manuals and user guides at all guides com...
Page 38: ...3 24 3 Disassembly and Reassembly Memo All manuals and user guides at all guides com...
Page 59: ...4 Troubleshooting 4 21 Memo All manuals and user guides at all guides com...
Page 85: ...5 26 5 Exploded Views and Parts List All manuals and user guides at all guides com...
Page 95: ...6 10 6 PCB Diagram Memo All manuals and user guides at all guides com...
Page 103: ...8 5 8 Schematic Diagram Memo All manuals and user guides at all guides com...