3-20
3. Disassembly and Reassembly
Part
Photo
Description
Inlet Valve &
Flow Meter
1. Place the dishwasher on its back and remove two
(2) screws on both sides of the cover front lower.
Remove the cover front lower.
2. Remove the water supply line (and elbow)
Caution
Make sure to close the faucet before removing the
water supply line.
3. Remove the four(4) screws on both sides of the
bracket front lower.
Remove the bracket front lower after the guide wire’s
4 hooks release .
* If the legs are in the way removing the screws,
unfasten it a little in the clockwise direction and
remove the screws.
4. Remove the two (2) screws and ground wire screw
from the inlet valve.
5. Hold and lift up the inlet valve and release flow
meter’s clasp on the bottom of the base.
* When release flow meter’s clasp, push-up using
tool.
6. Pull out the inlet valve until the hose clamp can be
removed, and remove the clamp and hose.
Caution
Take care when holding and removing the clamp
with a tool, as it may bounce and harm you.
All manuals and user guides at all-guides.com
Summary of Contents for DMR78 series
Page 14: ...2 6 2 Features and Specifications Memo All manuals and user guides at all guides com...
Page 38: ...3 24 3 Disassembly and Reassembly Memo All manuals and user guides at all guides com...
Page 59: ...4 Troubleshooting 4 21 Memo All manuals and user guides at all guides com...
Page 85: ...5 26 5 Exploded Views and Parts List All manuals and user guides at all guides com...
Page 95: ...6 10 6 PCB Diagram Memo All manuals and user guides at all guides com...
Page 103: ...8 5 8 Schematic Diagram Memo All manuals and user guides at all guides com...