3-2-2 Test Pattern (Aging Mode)
1. This mode can be used to confirm that the convergence and purity
adjustments are correct.
2. Access the Test Pattern parameters by pressing the CHANNEL keys
(
▲
,
▼
) while the Service Mode is on. The cursor will move to the
test pattern. Press the VOLUME keys. On-screen display:
3-2-3 V2 Tri-Norma Option Table
3-2-3(A) OPTION BYTE 0
RED
GREEN
BLUE
Table 3-2 Option Byte 0
DATA
D0
D1
D2
D3
D4
D5
D6
D7
FUNCTION
0 = AIR/STD/HRC/IRC
1 = AIR/STD/HRC/AFN
0 = NORMAL
1 = NO SIGNAL REACH 20MIN AUTO POWER OFF
O = AUTO MUTE
1 = NO AUTO MUTE
0 = HELP OSD OK IN OTHER LANGEUAGE
1 = HELP OSD NO
0 = NO AUTO POWER ON
1 = AUTO POWER ON
0 = MPX
1 = NO MPX
0 = NON LINEAR SHARPNESS
1 = LINEAR SHARPNESS
0 = NR EXECUTE
1 = NR SKIP
REMARK
OPTION
FIX = “0”
FIX = “1”
FIX = “0”
FIX = “0”
OPTION
FIX = “0”
FIX = “1 “
OPTION BYTE 0