- 40 -
YES
YES
YES
YES
YES
NO
NO
NO
NO
NO
resistance : 0 ~ 25Ω is normal
MΩ over is abnormal
Ass’y Display does not work.
Is Fuse OK?
Is Main PCB normal?
Are Ass’y Display and
Main PCB securely
connected?
Is the primary interlock
switch normal?
Is the power part of
PCB normal?
Replace Main PCB
Replace ASSY PCB
Close the door and check if the
Micro Switch is working properly.
Check whether parts
normally work after replaced.
Check whether it normally works
after appropriate parts are replaced
Check whether it normally works
after Main & Display are replaced.
Check connector
Replace Buttons
Replace Ass’y display
Replace a dial
Are buttons & a dial &
display normal?
Is the Flat wire
properly connected?
Flat wire No.1~7 :
5V is normal
Normal Operation
Make sure inspect the power relay after
replacing primary interlock switch, Secondary
interlock switch and door sensing switch.
* Latch switch assemblies
DOOR SENSING
INTERLOCK SWITCH
MONITOR INTERLOCK
SWITCH (BOTTOM)
PRIMARY INTERLOCK
SWITCH (TOP)
4-3-13 If Assy Display malfunction