- 35 -
NO
NO
NO
YES
YES
YES
LCD PCB Communication Error ( “E-83” )
: Check if the the connector soldering parts are
slightly shorted
: Check if the the connector soldering parts are
slightly shorted
Connect PCB to
assy display.
Remove any foeign
substance from
the shorted part.
Remove any foeign
substance from
the shorted part.
Replace the
PCB.
Perform the operation again and
check if it is working properly.
Does main PCB disconnect
to assy display?
Is the display connector(CN01)
part of the display PCB shorted?
Is the connector(CN201)
part of the main PCB shorted?
Perform the calibration
(Refer to page 18)
4-3-8 E-83