Alignment & Troubleshooting
Service Manual
4-58
Samsung Electronics
3) Fuser error
a) Low heat error
Lamp open?
(For 110V : 1.35
±
1 ohm
For 220V : 4.7
±
1 ohm)
"Error #U1-1211 Turn off then on"
message has occurred.
Change Fuser Lamp
4713-001243
Yes
NO
NO
NO
NO
NO
Change Fuser Lamp
4713-001243
Yes
AC-Harness Change
Yes
Replace Thermostat
4712-001031
Yes
Replace Thermostat
1404-001447
Yes
Replace Thermostat
1404-001447
Yes
Lamp Short?
AC-Harness Short?
Thermostat Open?
Thermostat Pollution, Bend?
NO
Thermostat Resistance Defect?
(300~450kohm @ 25
℃
)
Replace Fuser & recheck
The SMPS and Main B'd
could be suspect
Summary of Contents for CLP-320 Series
Page 39: ...Product spec and feature Service Manual 2 30 Samsung Electronics 2 3 8 Initailize Flow ...
Page 40: ...Product spec and feature Service Manual 2 31 Samsung Electronics ...
Page 60: ...Alignment Troubleshooting Service Manual 4 5 Samsung Electronics Configuration ...
Page 61: ...Alignment Troubleshooting Service Manual 4 6 Samsung Electronics supplies info ...
Page 62: ...Alignment Troubleshooting Service Manual 4 7 Samsung Electronics network ...
Page 125: ...Reference Information Service Manual 6 6 Samsung Electronics ...
Page 126: ...Reference Information Service Manual 6 7 Samsung Electronics ...
Page 127: ...Reference Information Service Manual 6 8 Samsung Electronics ...
Page 128: ...Reference Information Service Manual 6 9 Samsung Electronics ...