English 45
Tr
ouble
shoo
ting
Surface burner
Problem
Possible cause
Solution
All burners do not
light.
The power cord is not
plugged into the electrical
outlet.
Make sure the electrical plug is
plugged into a live, properly grounded
outlet.
A fuse in your home may
be blown or the circuit
breaker may have tripped.
Replace the fuse or reset the circuit
breaker.
The gas supply is not
properly connected or
turned on.
See the Installation instructions that
came with your range.
Surface burners do
not light.
The control knob is not set
properly.
Push in the control knob and turn it to
the
Lite
position.
The burner caps are not
in place.
The burner base is
misaligned.
Clean the electrodes.
Put the burner cap on the burner head.
Align the burner base.
Surface burner
clicks during
operation.
The control knob has been
left in the
Lite
position.
After the burner lights, turn the control
knob to a desired setting.
If the burner still clicks, contact a
service technician.
The burners do not
burn evenly.
Surface burner
components and caps are
not assembled correctly
and level.
Surface burners are dirty.
Clean surface burner components. (See
page
.)
Very large or yellow
surface burner
flames.
Wrong orifice is
assembled.
Check the burner orifice size and
contact your installer if you have the
wrong orifice (LP gas instead of natural
gas or natural gas instead of LP gas).
Problem
Possible cause
Solution
Surface burners
light but oven
burners do not light.
The Gas Pressure
Regulator shut off switch
is in the
OFF
position.
Call a qualified service technician.
Oven
Problem
Possible cause
Solution
The oven control
beeps and the
oven control
display shows an
information code.
There may be an issue
with your oven. See
the
.
Rotate both the mode and temperature
selector knobs to the
OFF
position and
restart the oven. If the problem persists,
disconnect all power to the range for at
least 30 seconds and then reconnect the
power. If this does not solve the problem,
call for service.
Very large or
yellow oven burner
flames.
The oven burner air
adjustment shutters
need to be adjusted.
Call for a qualified service technician.
The gas supply is not
properly connected or
turned on.
See the Installation instructions that came
with your range.
Wrong orifice is
assembled.
Check the burner orifice size and contact
your installer if you have the wrong orifice
(LP gas instead of natural gas or natural
gas instead of LP gas).
Oven temperature
is too hot or cold.
The oven temperature
needs to be adjusted
and recalibrated.
.
NX9900R_CHEF_NX36R9966PS_AA_DG68-01105A-01_EN+MES+CFR.indb 45
2019-03-08 12:33:16
Summary of Contents for Chef Collection NX36R9966P Series
Page 53: ...Memo NX9900R_CHEF_NX36R9966PS_AA_DG68 01105A 01_EN MES CFR indb 53 2019 03 08 12 33 17 ...
Page 54: ...Memo NX9900R_CHEF_NX36R9966PS_AA_DG68 01105A 01_EN MES CFR indb 54 2019 03 08 12 33 17 ...
Page 55: ...Memo NX9900R_CHEF_NX36R9966PS_AA_DG68 01105A 01_EN MES CFR indb 55 2019 03 08 12 33 17 ...
Page 109: ...Notas NX9900R_CHEF_NX36R9966PS_AA_DG68 01105A 01_EN MES CFR indb 53 2019 03 08 12 33 34 ...
Page 110: ...Notas NX9900R_CHEF_NX36R9966PS_AA_DG68 01105A 01_EN MES CFR indb 54 2019 03 08 12 33 34 ...
Page 111: ...Notas NX9900R_CHEF_NX36R9966PS_AA_DG68 01105A 01_EN MES CFR indb 55 2019 03 08 12 33 34 ...
Page 165: ...Notes NX9900R_CHEF_NX36R9966PS_AA_DG68 01105A 01_EN MES CFR indb 53 2019 03 08 12 33 52 ...
Page 166: ...Notes NX9900R_CHEF_NX36R9966PS_AA_DG68 01105A 01_EN MES CFR indb 54 2019 03 08 12 33 52 ...
Page 167: ...Notes NX9900R_CHEF_NX36R9966PS_AA_DG68 01105A 01_EN MES CFR indb 55 2019 03 08 12 33 52 ...