TW966
- 22 -
Installing over an kitchen furniture
If the underside of the appliance will be accessible
after installation, a separator panel
G (fig. 5A) will
need to be mounted maintaining the distances
shown (fig. 5B)..
To allow fresh air circulation there must be openings
in the kitchen furniture (fig. 5A) of the sizes indicated
in fig.5B.
Installing over an oven
If the appliance is installed over an oven the panel
is not necessary (fig. 6A - 6B)
To allow fresh air circulation there must be openings
in the kitchen furniture (fig.6A) of the sizes indicated
in fig.6B
IMPORTANT: if there is an oven under the
induction hob it is advisable for it to have a cooling
fan.Do not use the induction hob while
PYROLITIC
cleaning is in process.
WARNING: to allow the circulation of as
much fresh air as necessary, there must be at
least
40 mm between the induction hob module
and any appliance installed under it (fig. 6B).In any
event, adequate aeration must be provided.
�����
����
�����
����
���������
�����
Fig. 5A
Fig. 5B
�����
����
����
���������
�����
Fig. 6A
Fig.6B
Installing
(continued)
GB
- 23 -
Electrical connection
(Fig.7)
Before making the electrical connections, check
that:
-the ground cable is 2 cm longer than the other
cables;
-the system ratings meet the ratings indicated on
the identification plate fixed on the lower part of
the worktop;
-the system is fitted with efficient earthing compliant
to the laws and regulations in force.
Earthing is obligatory by law.
If the domestic appliance is fitted with a cable with
plug, must be installed in order that the socket is
easily accessible.
If the domestic appliance is fitted with a cable
without plug, an omnipolar switch must be
interposed with a minimum opening of 3 mm be-
tween the contacts and suited to the load indicated
on the plate and conform to the regulations in force
(the yellow/green ground conductor must not be
interrupted by the switch). When the appliance
has been installed, the omnipolar switch must be
easily reachable.
If the appliance is not fitted with a cable, use
type:"H05V2V2-F".
At no point must the cable reach a temperature
50°C higher than room temperature.
Installing
(continued)
�������������������������������������
�
�
�
�
�������������������������������������
�
�
�
�
�
�������������������������������������
�
�
����������������������������
�
������������������������������
�
����������������������������
�
Fig. 7
GB
Summary of Contents for C61IDGN0