Drain hose installation
1
If necessary, connect the 2-meter extension drain hose to the drain hose.
2
If you use the extension drain hose, insulate the inside of the extension drain hose
with a shield.
3
Fit the drain hose into 1 of 2 drain hose holes, then fix the end of the drain hose
tightly with a clamp.
If you don’t use the other drain hose hole, block it with a rubber stopper.
4
Pass the drain hose under the refrigerant pipe, keeping the drain hose tight.
5
Pass the drain hose through the hole in the wall. Check if it slants downwards as
seen in the picture.
The hose will be fixed permanently into position after finishing
the installation and the gas leak test; refer to page 11 for further details.
Shield
Drain hose
Extension drain hose
(No
default resource
)
When installing the drain hose for the indoor unit, check if condensation draining is adequate.
When passing the drain hose through the 65-mm hole drilled in the wall, check the following:
The hose must
NOT slant upwards.
The end of the drain
hose must NOT be
placed under water.
Do NOT bend the hose
in different directions.
Keep a clearance of at
least 5cm between the
end of the hose and
the ground.
Do NOT place the end
of the drain hose in a
hollow.
5c
m
le
ss
Ditch
6-Ways to connect Drain Hose and Pipe
Drain hose installation
Knock out
�