17
Samsung Electronics
5-2 Refrigerant Cycle Characteristic
5-2-1 Capacity Distributions
Capacity Distributions according to indoor and outdoor temperature variation.
■
COOLING MODE
- Indoor Temp. Variation : 21.0˚C ~ 32.4˚C
- Outdoor Temp. Variation : 25.0˚C ~ 45.0˚C
DB32.4 / WB24.0
DB30.6 / WB22.5
DB27.0 / WB19.0
DB24.0 / WB17.0
DB21.0 / WB15.0
Cooling Capacity(kW)
Cooling Capacity Distribution
4.0
3.0
2.0
1.0
25.0
35.0
45.0
Outdoor Temp.(DB C)
Indoor Temp.( C)
■
AS09HPBN
DB32.4/WB24.0
DB30.6/WB22.5
DB27.0/WB19.0
DB24.0/WB17.0
DB21.0/WB15.0
Cooling Capacity(kW)
Cooling Capacity Distribution
6.0
5.0
4.0
3.0
2.0
1.0
0.0
25
35
45
Outdoor Temp.(DB C)
Indoor Temp.( C)
■
AS12HPBN
DB98_20801A(1)_1 12/24/04 10:46 AM Page 17
Summary of Contents for AS09HPA
Page 62: ...MEMO 61 Samsung Electronics ...
Page 69: ...Samsung Electronics 68 11 PCB Diagram 11 1 ASS Y MAIN PCB DB93 02482A TOP ...
Page 70: ...69 Samsung Electronics PCB Diagram BOTTOM ...
Page 74: ...73 Samsung Electronics 11 2 ASS Y MELODY PCB DB93 02809A TOP BOTTOM ...