background image

17

Samsung Electronics

5. Block Diagram

HEAT EXCHANGER SENSOR

OPERATION

TIMER

TURBO

INDOOR FAN MOTOR

BUZZER

COMPRESSOR

OUTDOOR FAN MOTOR

4-WAY VALVE(*)

STEPPING MOTOR

: BLADE UP/DOWN

DISPLAY PART

IC-MCU

ROOM TEMPERATURE SENSOR

CONTROLLER

REMOTE CONTROL

INFRARED SIGNAL

RESET
CIRCUIT

OSCILLATION
CIRCUIT

POWER ON/OFF

TEMPERATURE

SELECT(UP/DOWN)

TURBO OPERATION

SLEEP OPERATION

TIMER
-ON TIMER
-OFF TIMER
-SET/CANCEL

MODE
(AUTO, COOL, DRY,
FAN, HEAT(*))

FAN SPEED SELECT

(H/M/L)

BLADE-H

MOVING SELECT

(SWING/STOP)

ENERGY SAVING

ZERO

VOLTAGE

DETECT

• BLADE CONTROL
• INDOOR FAN MOTOR CONTROL

• COMPRESSOR CONTROL

• TEMPERATURE CONTROL

• TIMER

• BUZZER CONTROL

• OUTDOOR FAN MOTOR CONTROL

• 4-WAY VALVE CONTROL(*)

TRIGER

SIGNAL

SSR

RPM

DETECT

• COMPRESSOR DRIVE
• OUTDOOR FAN MOTOR 

DRIVE

• STEPPING MOTOR DRIVE

• BUZZER DRIVE

• 4-WAY VALVE DRIVE(*)

• COMPRESSOR CONTROL

SIGNAL

• STEPPING MOTOR

CONTROL SIGNAL

• BUZZER CONTROL SIGNAL

• OUTDOOR FAN MOTOR 

CONTROL SIGNAL

• 4-WAY VALVE CONTROL

SIGNAL(*)

DC 5V

DC 12V

AC INPUT

SMPS POWER BLOCK

VOLTAGE REGULATOR

(*)marks : In case of heat pump model.

 Tsar_DB98_15869A(1)_1  1/12/04 10:05 AM  Page 17

Summary of Contents for AS05Z1AZD

Page 1: ...S05Z1AZD AS07Z1AZD SERVICE Manual CONTENTS AIR CONDITIONER 1 Product Specifications 2 Disassembly and Reassembly 3 Set Up the Model Option 4 Exploded Views and Parts List 5 Block Diagram 6 Schematic Diagram ROOM AIR CONDITIONER ...

Page 2: ...igerant to Change R22 g Protection Device OLP Cooling Test Condition Maximum Operation Condition SH05ZZ8 SH07ZZ8 Wall mounted 5 000 5 000 0 9 4 3 19 4 5 19 33 48 33 48 10 2 10 8 1 220 240 50 490 460 2 3 2 2 92 6 90 9 17 0 250V 10 16A 728x255x155 660x470x240 28 6x10 0x6 1 26 0x18 5x9 5 7 25 5 ø6 35 x 5 ø9 52 x 5 ø18 x 2 000 Rotary Cross flow Propeller steel steel 11 20 2ROW 10STEP 1ROW 20STEP CAPIL...

Page 3: ...0 1 220 240 50 490 2 2 98 8 17 0 250V 10 16A 728x255x155 660x470x240 28 6x10 0x6 1 26 0x18 5x9 5 7 24 5 ø6 35 x 5 ø9 52 x 5 ø18 x 2 000 Rotary Cross flow Propeller steel steel 11 20 2ROW 10STEP 1ROW 20STEP CAPILLARY TUBE 360 440 RAC12051 1208 Wall mounted 5 000 0 9 4 3 19 33 48 11 3 1 200 220 50 440 2 2 90 9 16 5 250V 10 16A 728x255x155 660x470x240 28 6x10 0x6 1 26 0x18 5x9 5 7 24 5 ø6 35 x 5 ø9 5...

Page 4: ...rocedure Remark 1 Front Grille 1 Stop the air conditioner operation and block the main power 2 Detach tape of Grille Air Inlet 3 After Both End Part of the Grille Lower Position are pressing it shall be detach by pushing up 4 Loosen 1 of the right screw and detach the Terminal Cover 5 Detach the thermistor from the Front Grille 6 Loosen 3 fixing screws of Front Panel ...

Page 5: ... to disassemble the Panel Front press in order the left center and right of the upper side of the Panel Grille with the plam of the hand to remove the hook And then disassemble the Panel Grille 1 Pull Tray Drain out from the Back Body 1 Take all the connector of PCB upper side out Inclusion Power Cord 2 Detach the outdoor unit connection wire from the Terminal Block 3 If pulling the main PCB up it...

Page 6: ...e 3 Detach the Holder Pipe at the rear side 4 Loosen the 2 fixing screws of right and left side 5 Lifting the Heat Exchanger up a little to push the up side for separation from the indoor unit 1 Loosen the 4 fixing screws and detach the Motor Holder 2 Loosen the fixing screw of Fan Motor with a M3 wrench 3 Detach the Fan Motor from the Fan 4 Detach the Fan from the left Holder Bearing ...

Page 7: ...ing screws and detach the Cover Terminal 2 Loosen 2 fixing screws and detach the Cover Control 3 Detach the connection wire from the Terminal Block 4 Loosen 6 fixing screws and detach the Cabinet Front 5 Loosen 1 fixing screw of Ass y E part 6 Loosen 12 fixing screws and detach the Cabinet Side ...

Page 8: ...etach the Motor 4 Loosen 2 fixing screws and detach the Motor Bracket from the Base 1 Loosen 2 fixing screws of left and right side 2 Disassemble the inlet and outlet pipe by welding 3 Detach the Heat Exchanger 1 Open the Terminal Cover of Compressor and unscrew the Connection Terminal 2 Disassemble the inlet and outlet pipe of Compressor by Welding 3 Loosen 3 bolts of the lower part 4 Detach the ...

Page 9: ...y time you push the button the display panel reads or repeatedly Do not touch the button because its default is Unless the display panel reads push the button to Setting is not required if you must a value which has a default 3 Push the button to set the display panel to Every time you push the button the display panel reads repeatedly 4 Do not touch the button because its default is Unless the di...

Page 10: ...o set the display part to and check the display part The display part shows Press the Mode Selection key to set the display part to and check the display part The display part shows Step 4 Press the ON OFF button When pressing the operation ON OFF key with the direction of remote controller for unit the sound Ding or Diriring is heard and the OPERATION ICON lamp of the display is flickering at the...

Page 11: ...TION ITEMS REMOCON MODEL SEG1 SEG2 SEG3 SEG4 SEG5 SEG6 SEG7 SEG8 SEG9 SEG10 SEG11 SEG12 SH05ZZ8 SH07ZZ8 0 0 5 0 2 5 1 7 0 2 1 d 0 0 5 0 2 4 1 7 0 3 6 0 SC05ZZ8 0 0 0 0 0 0 1 7 0 2 1 d AS05Z1AZD 0 0 0 0 0 0 1 7 0 2 1 d AS07Z1AZD 0 0 0 0 0 0 1 7 0 2 1 d ...

Page 12: ...MEMO 11 Samsung Electronics ...

Page 13: ...1 1 4 1 5 5 1 5 4 5 2 1 3 1 2 4 2 4 5 5 5 3 3 4 3 3 3 5 3 2 3 1 9 2 1 2 2 4 1 4 3 10 1 10 2 You can search for the updated part code number through the ITSELF URL http itself sec samsung co kr 4 Exploded Views and Parts List 4 1 Indoor Unit ...

Page 14: ... 3 DB93 02534A ASS Y DISPLAY PCB ASS Y 1 1 1 3 4 DB63 00865A COVER DISPLAY PCB HIPS 1 1 1 3 5 DB61 01657A HOLDER LED HIPS 1 1 1 4 DB93 02513A ASS Y CONTROL IN ASS Y 1 DB93 02513B ASS Y CONTROL IN ASS Y 1 1 4 1 DB61 01656A HOLDER CONTROL HIPS V0 1 1 1 4 2 DB93 02617A ASS Y MAIN PCB ASS Y 1 DB93 02617B ASS Y MAIN PCB ASS Y 1 1 4 3 DB62 01661A HOLDER CLAMP IN SGCC M 1 1 1 5 DB94 00314A ASS Y TRAY DRA...

Page 15: ...Samsung Electronics 14 4 2 Outdoor Unit 14 2 14 1 23 24 22 11 2 1 7 14 8 10 12 15 16 5 3 6 21 19 20 18 17 4 9 9 1 13 2 13 6 13 1 13 13 3 13 5 13 4 ...

Page 16: ...00109B ASS Y CABI SIDE 1 1 1 1 1 13 DB93 02608A ASS Y CONTROL OUT 1 DB93 02565A ASS Y CONTROL OUT 1 DB93 02565B ASS Y CONTROL OUT 1 DB93 02608B ASS Y CONTROL OUT 1 DB93 02608C ASS Y CONTROL OUT 1 13 1 2501 001235 C OIL 1 1 2501 001234 C OIL 1 1 1 13 2 DB93 00481A ASS Y LEAD WIRE 1 1 1 1 1 13 3 DB61 00172A HOLDER CAPACITOR 1 1 1 1 1 13 4 DB65 40049E TERMINAL BLOCK 1 1 1 1 1 13 5 2301 001375 C FILM ...

Page 17: ...56A DB93 02617A DB93 02508A DB61 01661A 6001 000929 6001 001054 6001 000725 DB61 00171A 3903 000095 DB32 00020A DB93 02498A DB39 00147D DB61 01656A DB93 02617B DB93 02507A DB61 01661A 6001 000929 6001 001054 6001 000725 DB61 00171A 3903 000095 DB32 00020A DB93 02498A DB39 00147D DB61 01656A DB93 02617B DB93 02507A DB61 01661A 6001 000929 6001 001054 6001 000725 DB61 00171A DB93 01631A DB32 00020A ...

Page 18: ...E AUTO COOL DRY FAN HEAT FAN SPEED SELECT H M L BLADE H MOVING SELECT SWING STOP ENERGY SAVING ZERO VOLTAGE DETECT BLADE CONTROL INDOOR FAN MOTOR CONTROL COMPRESSOR CONTROL TEMPERATURE CONTROL TIMER BUZZER CONTROL OUTDOOR FAN MOTOR CONTROL 4 WAY VALVE CONTROL TRIGER SIGNAL SSR RPM DETECT COMPRESSOR DRIVE OUTDOOR FAN MOTOR DRIVE STEPPING MOTOR DRIVE BUZZER DRIVE 4 WAY VALVE DRIVE COMPRESSOR CONTROL...

Page 19: ...Samsung Electronics 18 6 Schematic Diagram 6 1 Indoor Unit This Document can not be used without Samsung s authorization ...

Page 20: ...e Manual is a property of Samsung Electronics Co Ltd Any unauthorized use of Manual can be punished under applicable International and or domestic law Samsung Electronics Co Ltd Jan 2004 Printed in Korea Code No DB98 15869A 1 ...

Reviews: