After completing the installation, always carry out a functional test and provide the instructions on how to operate the air 

conditioner to the user.

 

Do not use the air conditioner in environments with hazardous substances or close to equipment that release free flames to 

avoid the occurrence of fires, explosions or injuries.

 

To help prevent injury when accidentally touching the indoor unit fan, install the indoor unit at least 2.5 m above the floor.

  The air conditioner should be used only for the applications for which it has been designed : the indoor unit is not suitable 

to be installed in areas used for laundry.

  Our units must be installed in compliance with the spaces indicated in the installation manual to ensure either accessibility 

from both sides or ability to perform routine maintenance and repairs. The units’ components must be accessible and that 

can be disassembled in conditions of complete safety either for people or things.  

For this reason, where it is not observed as indicated into the Installation Manual, the cost necessary to reach and repair the 

unit (in safety, as required by current regulations in force) with slings, trucks, scaffolding or any other means of elevation 

won’t be considered in-warranty and charged to end user.

Power supply line, fuse or circuit breaker

 

Always make sure that the power supply is compliant with current safety standards. Always install the air conditioner in 

compliance with current local safety standards.

 

Always verify that a suitable grounding connection is available.

  Verify that the voltage and frequency of the power supply comply with the specifications and that the installed power is 

sufficient to ensure the operation of any other domestic appliance connected to the same electric lines.

  Always verify that the cut-off and protection switches are suitably dimensioned.

  Verify that the air conditioner is connected to the power supply in accordance with the instructions provided in the wiring 

diagram included in the manual.

  Always verify that electric connections (cable entry, section of leads, protections…) are compliant with the electric 

specifications and with the instructions provided in the wiring scheme.  

Always verify that all connections comply with the standards applicable to the installation of air conditioners.

Indoor unit

  For Wi-Fi Air-conditioner installation, select indoor unit location near to wireless router.

     In case Wi-Fi signal strength weakened , Smart APP may be disconnected depending on the Wi-Fi signal strength.

  Where airflow is not blocked.

  Where cool air can be distributed throughout the room.

  Install the refrigerant piping length and the height difference of both indoor and outdoor units as indicated in the 

installation diagram.

  Wall that prevents vibration and is strong enough to hold the product weight.

  Out of the direct sunlight .

  1 m or more away from the TV or radio (to prevent the screen from being distorted or noise from being generated).

  As far away as possible from the fluorescent and incandescent lights (so that the remote controller can be operated well).

  A place where the air filter can be replaced easily. 

  Don't install directly above electronics equipment as leaking water may cause damage if not serviced. (eg. Computers, TV, etc). 

Choosing the installation location

English-29

INST
ALL
ATION

05

A3050 FA_IB&IM_DB68-04003A_HP_EN.indd   29

2013-12-25   15:27:41

Summary of Contents for AR FQSS Series

Page 1: ...A3050 FA_IB IM_DB68 04003A_HP_EN indd 1 2013 12 25 15 27 30...

Page 2: ...ntering into the product or accumulating on the filter Smart Install When the installation is done your product will examine itself through trial operation to check if it was installed properly EasyIn...

Page 3: ...Fixing the installation plate 34 Disassembling Assembling the Cover panel for indoor unit installation 35 Connecting the assembly cable 37 Installing and connecting the assembly pipe of the indoor un...

Page 4: ...the power line with the power specifications of the product or higher and use the power line for this appliance only In addition do not use an extension line Extending the power line may result in el...

Page 5: ...e or problems with the product Install the draining hose properly so that water is drained correctly Failing to do so may result in water overflowing and property damage Avoid adding drain to waste pi...

Page 6: ...e center Failing to do so may result in problems with the product water leakage electric shock or fire A delivery service for the product is not provided If you reinstall the product in another locati...

Page 7: ...ING WARNING Do not place an object near the outdoor unit that allows children to climb onto the machine This may result in children seriously injuring themselves Do not use this air conditioner for lo...

Page 8: ...the appliance with wet hands This may result in electric shock Do not spray volatile material such as insecticide onto the surface of the appliance As well as being harmful to humans it may also resu...

Page 9: ...ectric shock or fire Before cleaning or performing maintenance cut off the power supply and wait until the fan stops Failing to do so may result in electric shock or fire FOR CLEANING CAUTION Take car...

Page 10: ...cle is actuated to help remove frost from an outdoor unit that may have deposited at low temperatures The internal fan is switched off automatically and restarted only after the defrost cycle is compl...

Page 11: ...del Checking the name of the parts Display Power button Remote controller receiver Air filter Air flow blade upanddown Air flow blade leftandright Air intake Virus Doctor indicator Timer Auto clean in...

Page 12: ...Medium High Turbo Cancel Cancel the timer mode Beep off To silence the beep sound when pressing the button Vertical air swing Activate Deactivate air flow blade movement automatically up and down Set...

Page 13: ...long time remove the batteries from the remote controller and store it Inserting the batteries 1 Push the lever as arrow indicates on the rear side of the remote controller and pull up 2 Insert two A...

Page 14: ...he desired coolness Dry The air conditioner in Dry mode acts like a dehumidifier by removing moisture from the indoor air Dry mode makes the air feel refreshing in a humid climate To activate the Dry...

Page 15: ...o Dry Auto Fan Low Med High Turbo Heat Auto Low Med High Turbo Press the button to adjust the temperature Auto 2 Step Cooling or Heat You can adjust the desired temperature by 1 C within the range of...

Page 16: ...dled Blade pin lever Press the Vertical airswing button on the remote controller Air swing indicator will be on the remote controller display and air flow blades move up and down continuously to circu...

Page 17: ...ion your air conditioner will operate more powerfully to quickly cool your room Press the Fast Comfortbutton twice when the Fast function is on Cancel Comfort function is only available in Cool mode I...

Page 18: ...n speed will be adjusted automatically according to the mode However I f you select mode while heating operation is on you can adjust fan speed When the mode is on In Cool mode Air flow direction will...

Page 19: ...Dry Heat mode 1 Press the OnTimer OffTimer button On Off timer indicator will blink on the remote controller display 2 Press the TimeUp or TimeDown button to set the time You can set the time in half...

Page 20: ...utes Auto heat Heat Fan mode approximately 15 minutes CombiningOnTimerandOffTimer Iftheairconditionerison Iftheairconditionerisoff PresettimeonOntimerislongerthanOfftimer Ex On timer 3 hours Off timer...

Page 21: ...inCoolmode appears on the remote controller display for few seconds and disappears Single User indicator and air swing indicator appear automatically on the remote controller display The air flow blad...

Page 22: ...hould use a micro fiber cloth to clean the panel When you use the micro fiber cloth slightly dampen the cloth and remove any debris on the cloth to avoid scratches Heatexchanger Illustration may diffe...

Page 23: ...Remove the Air filter from the main body Insert the Air filter back in its original position Dry the Air filter in a ventilated area Clean the Air filter with a vacuum cleaner or soft brush If dust is...

Page 24: ...e top of the Air filter into the the main body Air filter 2 There s one hook in both side of the filter press the surface of the Air filter softly and get the hooks into the main body 3 Press the bott...

Page 25: ...pan 2 Thoroughly clean the heat exchanger 2 Clean the cross fan 2 Clean the condensate drain pipe 2 Replace the remote controller batteries 1 Outdoor unit Clean the heat exchanger on the outside of t...

Page 26: ...ydirt Ifthereisalotofduston theAirfilter cooling heating performancemaydecrease Clean themfrequently Checkiftheoutdoorunitiscoveredorinstalledneartheobstacle Takethecoveroffandtaketheobstacleaway Chec...

Page 27: ...ervicecenter Odorspermeatein theroomduring operation Checkiftheapplianceisrunninginasmokyarea Ventilatethe roomoroperatetheairconditionerinFanmodefor1 2hours Wedonotusesmellycomponentsintheairconditio...

Page 28: ...eas used for laundry Do not use the units if damaged If problems occur switch the unit off and disconnect it from the power supply In order to help prevent electric shocks fires or injuries always sto...

Page 29: ...the power supply comply with the specifications and that the installed power is sufficient to ensure the operation of any other domestic appliance connected to the same electric lines Always verify th...

Page 30: ...r than 2 4 m or directly under eaves for accessibility for service and OH S reasons Avoid the following places to prevent malfunction of the unit Where there is machine oil Salty environment such as s...

Page 31: ...The upper part of the outdoor unit and the air outlet is opposite the wall When the walls are blocking front and the rear side of the outdoor unit 300 or more 1500 or more Top view Side view Air outl...

Page 32: ...t on the product Installation must be done in level and in a place where vibration will not cause any effect The following accessories are supplied with the air conditioner The number of each accessor...

Page 33: ...eWrench Pipe Cutter Reamer Pipe Bender Spirit Level Screw Driver Spanner Drill LWrench MeasuringTape Tools for test operations Thermometer Resistance Meter Electroscope Optional accessories The follow...

Page 34: ...frame 2 Attach the wooden uprights to the window frame giving attention to the weight of the indoor unit 3 Attach the installation plate to the wooden upright using tapping screws If you fix the indoo...

Page 35: ...isassemble the cover panel Cap Screw Remove the Cap screw Unfasten the screw Cover Panel Removing the Cover panel Before mounting the indoor unit Cover panel is fixed to a main body of the product wit...

Page 36: ...shing it up at an angle Assembling the Cover panel After mounting the indoor unit To assemble the Cover panel proceed in reverse order of disassembling Use both hands for assembling and be extra caref...

Page 37: ...me a fire hazard due to overheating of the electrical contact during a wiring work 1 Extend the assembly cable if necessary Do not connect two or more different cables to extend the length It may caus...

Page 38: ...re terminal numbers on the indoor outdoor unit matches Please ensure that Power Communication cables are separated they must not be in the same cable 10 Connect the grounding conductor to the groundin...

Page 39: ...ure for the refrigerant pipe varies according to the exit position of the pipe when facing the wall Right A Left B Underside C Rear B A C Outer Diameter Torque N m kgf cm 6 35 mm 14 18 140 180 9 52 mm...

Page 40: ...d a pipe longer than 4 or 5 meters You must add refrigerant to the pipes otherwise the indoor unit may freeze Cutting or extending the pipe 1 Unscrew the caps at the end of each pipe All inert gas exh...

Page 41: ...ue 7 For further details on how to connect to the outdoor unit and evacuate the air refer to page 44 46 Correct Uneven Thickness Cracked Damaged Surface Inclined Excessive torque can be cause of gas l...

Page 42: ...a clamp 4 When extending the Drain Hose hold the end of Drain Hose and Extended Hose rotate and insert the drain hose into Extended hose for 40 45 mm Make sure the two hoses are firmly connected there...

Page 43: ...ater does not overflow onto the electrical part Change the direction only when it is necessary 1 Detach the rubber cap with the pliers 2 Detach the drain hose by pulling it and turning to the left 3 I...

Page 44: ...erant Do not vent R 410A into atmosphere it is a fluorinated greenhouse gas covered by Kyoto Protocol with a GlobalWarming Potential GWP 1975 You should evacuate the air in the indoor unit and in the...

Page 45: ...pressure side of manifold gauge clockwise Turn off the vacuum pump Check for 2 minutes if there is any pressure change Remove the hose of the low pressure side of manifold gauge 6 Set a valve cork of...

Page 46: ...ation regulation regarding the refrigerant used Charging the refrigerant under conditions of liquid by using a liquid pipe a Factory refrigerant charge of the product see unit name plate b Additional...

Page 47: ...gerant tubing in order to avoid refrigerant loss to the atmosphere Shut off the liquid valve with the Allen wrench Turn the system on in cooling with fan operating at high velocity Compressor will imm...

Page 48: ...or unit as indicated on the top of the unit to let the discharged air out properly 2 Fix the outdoor unit in level to an appropriate support using anchor bolts 3 If the outdoor unit is exposed to stro...

Page 49: ...ed for pipe extension 2 Status of the indicator after supplying the power Standby status 2 When the air conditioner is in standby status use the remote controller to start the Smart Install mode 1 Pre...

Page 50: ...ssary measures when error occurs Refer to the service manual for necessary measures for each error that occurs 2 Use the product after taking care of the error that occurs Error indicator Error Measur...

Page 51: ...k Inlet air temp Outlet air temp From 10 C to 12 C indicative deltaT Heating mode indoor unit check Outlet air temp Inlet air temp From 11 C to 14 C indicative deltaT In heating mode the indoor fan mo...

Page 52: ...ion tape twice and position your contraction tube in the middle of the insulation tape 5 Apply heat to the contraction tube to contract it 6 After tube contraction work is completed wrap it with the i...

Page 53: ...English 53 OTHERS 04 A3050 FA_IB IM_DB68 04003A_HP_EN indd 53 2013 12 25 15 28 01...

Page 54: ...rica_fr Senegal 800 00 0077 Cameroon 7095 0077 KENYA 0800 545 545 www samsung com UGANDA 0800 300 300 TANZANIA 0685 88 99 00 RWANDA 9999 BURUNDI 200 DRC 499999 SUDAN 1969 South Africa 0860 SAMSUNG 726...

Page 55: ...at www samsung com register This manual is made with 100 recycled paper AR FQSS Series AR FPSS Series Air Conditioner user installation manual imagine the possibilities ThankyouforpurchasingthisSamsu...

Reviews: