3-12
Samsung Electronics
Operating Instructions and Installation
3-2-2(i) Refrigerant Adjustment
3-2-2(j) Flare unt fixing torque
Class
For installation
For service
Outter diameter
ø 6.35 (9000Btu, 12000Btu) (Liquid Side)
ø 9.52 (9000Btu) (Gas Side)
ø 12.7 (12000Btu) (Gas Side)
160
300
500
200
350
550
Fixing Torque Final Torque
Torque (kg-cm)
Connection
Pipe Length
5m Max.
5~10m
Air-Purge
Method
Refer to the
detailed Air-Purge
Procedure
Refrigerant
Adjustment
Unnecessary
Add 10g of refrigerant
R407C(Add as liquid
state) for every 1m.
Air-Purge
Method
Purge air using a
vaccum pump
Refrigerant
Quantity
refer to
specification sheet
Add 10g of refrigerant
R407C(Add as liquid
state) for every 1m.
• MODEL NAME : AQ07ACVE/ SH07CA1
Low Pressure(kg/cm2G)
Pressure Graph
Outdoor inlet air D.B. temp
7.00
6.00
5.00
4.00
3.00
20
25
30
35
40
45
21.5/15.0
27.0/19.0
32.4/24.0
• MODEL NAME : AQ07ACVE/ SH07CA1
Low Pressure(kg/cm2G)
Pressure Graph
Outdoor inlet air D.B. temp
7.00
6.00
5.00
4.00
3.00
20
25
30
35
40
45
21.5/15.0
27.0/19.0
32.4/24.0
• MODEL NAME : AQ09ACVE/ SH09CA1
Low Pressure(kg/cm2G)
Pressure Graph
Outdoor inlet air D.B. temp
7.00
6.00
5.00
4.00
3.00
20
25
30
35
40
45
21.5/15.0
27.0/19.0
32.4/24.0
OIAIN-5 5/31/01 1:54 PM Page 3-12
Summary of Contents for AQ07ACVE
Page 2: ...ELECTRONICS Samsung Electronics Co Ltd Mar 2000 Printed in Korea Code No DB81 00143A 1 ...
Page 4: ...1 2 MEMO Samsung Electronics ...
Page 8: ...2 4 MEMO Samsung Electronics ...
Page 22: ...3 14 Samsung Electronics MEMO ...
Page 28: ...4 6 MEMO Samsung Electronics ...
Page 48: ...6 7 Samsung Electronics MEMO ...
Page 50: ...Samsung Electronics 8 1 8 PCB Diagrams 8 1 1 Main PCB ...