Operating temperature and humidity range
If the product is not operating within the operating temperature and humidity range, operation may stop since protective
device will trigger.
Classification
Indoor temperature
Outdoor temperature
Indoor humidity
Cool mode
18
°
C
~ 32
°
C
-5
°
C
~ 48
°
C
relative humidity under 80 %
Dry mode
18
°
C
~ 32
°
C
-5
°
C
~ 48
°
C
-
Heat mode
Under 27
°
C
-20
°
C
~ 24
°
C
-
❋
❋
If you operate the product in Cool mode for a longtime when humidity is high, dew may form on the surface of the
product.
❋
❋
To use the product as main heating apparatus, another load estimation is necessary. Use low temperature product which
the effectiveness of heating is high. (Please contact a service center.)
❋
❋
Outdoor temperature standard for rated heating capacity is 7
°
C . If outdoor temperature becomes below 0
°
C, it may
decrease due to temperature condition.
Precautions before operation
X
f
refrigerant used in air conditioner is non-toxic and non-flammable. However, when the air conditioner is installed in
small space, extra ventilation system is required in case of refrigerant leakage.
X
f
If you are using heat pump model, mixed operation mode is not available when the indoor units are connected to same
outdoor unit.
❋
❋
Mixed operation mode is that two or more indoor units, connected to one outdoor unit, operating in different
operation mode simultaneously.