ENGLISH-80
Setting outdoor unit option switch and key function
K1
K2
K3
K4
< A type >
< B type >
K4 (Number of
press)
KEY operation
Display on segment
SEG 1
SEG2, 3, 4
1 time
Outdoor unit model
1
AM120
✴
XW
✴
Off, 1, 2
2 times
Target frequency (Compressor 1)
2
120 Hz
1, 2, 0
3 times
Target frequency (Compressor 2)
3
120 Hz
1, 2, 0
4 times
High pressure (MPa)
4
1 .52 MPa
1, 5, 2
5 times
low pressure (MPa)
5
0 .43 MPa
0, 4, 3
6 times
Discharge temperature (Compressor 1)
6
87 °C
0, 8, 7
7 times
Discharge temperature (Compressor 2)
7
87 °C
0, 8, 7
8 times
IPM temperature (Compressor 1)
8
87 °C
0, 8, 7
9 times
IPM temperature (Compressor 2)
9
87 °C
0, 8, 7
10 times
CT sensor value (Compressor 1)
A
2 A
0, 2, 0
11 times
CT sensor value (Compressor 2)
B
2 A
0, 2, 0
12 times
Suction temperature
C
-42 °C
-, 4, 2
13 times
COnD OUT temperautre
D
-42 °C
-, 4, 2
14 times
Temperature of liquid pipe
E
-42 °C
-, 4, 2
15 times
TOP temperature (Compressor 1)
F
-42 °C
-, 4, 2
16 times
TOP temperature (Compressor 2)
G
-42 °C
-, 4, 2
17 times
Water temperature
H
-42 °C
-, 4, 2
18 times
EVI inlet temperature
I
-42 °C
-, 4, 2
19 times
EVI outlet temperature
J
-42 °C
-, 4, 2
20 times
Main EEV 1 step
K
2000 steps
2, 0, 0
21 times
Main EEV2 step
l
2000 steps
2, 0, 0
22 times
EVI EEV step
M
300 steps
3, 0, 0
23 times
HR EEV step
n
2000 steps
2, 0, 0
24 times
-
O
-