Step 9 Installing the drain hose
When installing the drain hose for the indoor unit, check if
condensation draining is adequate. When passing the drain
hose through the 65-mm hole drilled in the wall, check the
following:
The hose must
NOT slant
upwards.
5 cm
less
Ditch
The end of the
drain hose must
NOT be placed
under water.
Do NOT bend the
hose in different
directions.
Keep a clearance
of at least 5cm
between the end
of the hose and
the ground.
Do NOT place the
end of the drain
hose in a hollow.
1
If necessary, connect the 2-meter extension drain hose
to the drain hose.
2
If you use the extension drain hose, insulate the inside
of the extension drain hose with a shield.
3
Fit the drain hose into 1 of 2 drain hose holes, then fix
the end of the drain hose tightly with a clamp.
Shield
Drain hose
Extension drain hose
NOTE
•
If you don’t use the other drain hose hole, block it with
a rubber stopper.
4
Pass the drain hose under the refrigerant pipe, keeping
the drain hose tight.
5
Pass the drain hose through the hole in the wall. Check
if it slants downwards as seen in the picture.
NOTE
•
The hose will be fixed permanently into position after
finishing the installation and the gas leak test; refer to
page 12 for further details.
•
DO NOT WALL UP THE DRAIN HOSE CONNECTION!
Drain hose connection must be easy accessible and
serviceable.
Step 10 Optional: Changing direction
of the drain hose
You can select the direction of the drain hose, depending
on where you want to install the indoor unit.
1
Detach the rubber cap with the flyer.
Drain hose
Screw hole
Screw
2
Detach the drain hose by pulling it and turning to the left.
3
Insert the drain hose by fixing it into the groove of the
drain hose and the outlet of the drain pan.
Drain pan
outlet
Rubber cap
4
Attach the rubber cap with a screwdriver by turning it
to the right until it fixes to the end of the groove.
DVM Boracay_IM_EN_DB68-06417A-00_16.09.22.indd 10
2016/9/22 11:29:13