28
Setting an indoor unit address and installation option
The output of hot water heater in SEG9 is generated from the hot coil part of the terminal board in duct models.
F4
F3
F1 F2
V2
V1
1(L) 2(N)
2
1
HOT
COIL
AC
POWER
OUTDOOR
COMMUNICATION
Wire Remote
Controller
DC
12 V
* The output of hot coil terminal is AC 220 V / 230 V
(The same as Indoor Unit’s input Power)
COM1
COM2
(+)
L
N
(-)
The external output of SEG15 is generated by MIM-B14 connection. (Refer to the manual of MIM-B14.)
02 series installation option(Detailed)
Option No. : 02XXXX-1XXXXX-2XXXXX-3XXXXX
Option
SEG1
SEG2
SEG3
SEG4
SEG5
SEG6
Explanation
PAGE
MODE
Use of robot cleaning
Use of external room temperature
sensor / Minimizing fan operation when
thermostat is off
Use of central control
FAN RPM compensation
Remote
Controller
Display
Indication
and Details
Indication Details Indication
Details
Indication
Details
Indication
Details
Indication
Details
Indication
Details
Use of
External
room
temperature
sensor
Minimizing
fan
operation
when
thermostat
is off
0
2
0
Disuse
0
Disuse
Disuse
0
Disuse
0
Disuse
1
Use
Disuse
1
RPM
compensation
1
Use
2
Disuse
Use
(
*1
)
1
Use
2
High ceiling
KIT
3
Use
Use
(
*1
)
Option
SEG7
SEG8
SEG9
SEG10
SEG11
SEG12
Explanation
PAGE
Use of drain pump
Use of hot water heater
EEV Step when heating
stops
Remote
Controller
Display
Indication
and Details
Indication Details Indication
Details
Indication
Details
Indication
Details
Indication
Details
Indication
Details
1
0
Disuse
0
Disuse
0
Default
value
1
Use
1
Use (
*2
)
1
Noise
decreasing
setting
2
When an
indoor unit
stops, drain
pump will
operate for
3min
2
--
3
Use
(
*2
)