ENGLISH-8
Indoor/outdoor unit installation diagram
Maximum
allowable piping
elevation 10 m
or less
6 m or
less
Install S-trap for
every 6 m
Maximum allowable
piping length 20 m
or less
Outdoor unit
50 cm
or more
30 cm or
mor
e
50 cm or
more
air guide
(Not provided by
manufacturer )
30 cm or more
20 cm or more
No obstacle 1 m
or mor
e
60 cm or mor
e
30 cm
or more
Protection
vinyl
Outdoor
unit leg
Rubber leg
Spare space for piping
• One S-trap must be installed on the low pressure
pipe up to 6 m of piping elevation . For piping
elevation that exceeds 6 m, install S-trap every
6 m .
CaUtION
Piping length for indoor/outdoor unit installation
▶
Refer to illustration on the left for maximum allowable
piping length and elevation .
▶
Since product performance and lifespan may decrease as
piping length becomes longer, try to minimize the piping
length but make sure it is over 5 m .
▶
Select the installation location where you can keep the
piping bending to maximum 10 spots .
▶
Stated cooling performance is based on product with 5 m
piping .
Installation space for floor type indoor unit
▶
To minimize the waste of space due to installation, install the indoor unit as
shown in below figure .
-
top view
❋
❋
After completing the installation, remove the protection vinyl .
(Be careful of static electricity) .
❋
❋
After completing the installation, remove the protective
filament film on the product .
• Make sure that there are no obstacles (such as curtains etc .) blocking air
inlets of the indoor unit .
• Clear space on the right side of the indoor unit for possible filter
maintenance in the future .
CaUtION
When air guide needs to be installed to prevent the warm discharge air from
disturbing the pedestrian, refer to the illustration on the right side for installation .