![Samsung AEGIS WF-M592NMH Service Manual Download Page 53](http://html.mh-extra.com/html/samsung/aegis-wf-m592nmh/aegis-wf-m592nmh_service-manual_358435053.webp)
38 _ Troubleshooting
Error Type
Drum
Fully
automatic
Causes
Remarks
Error
mode
Old
error
mode
For USA
Temperature
Sensor Error
tE1
tE1
6E
tE
-
- The washing heater in the tub has an error.
(Contact error, temperature sensor fault)
- The connector is connected incorrectly or is
disconnected.
- If the water level sensor operates without water
because the water is frozen or for any other
reason and the temperature sensor engaged at
the bottom to prevent overheating for the washing
heater detects a temperature of 100 to 150 ˚C,
the washing machine turns the input power off.
Heater sensor
fault
: When the
connector is
connected
incorrectly or
has a wire
disconnected
or contact error
tE2
tE2
-
-
- The temperature sensor for the duct assy fan
housing is faulty.
(A sensor fault such as an internal short-circuit or
wire disconnection)
- The connector is out of place or has a contact
error.
Duct
condensing
temperature
sensor fault (for
models before
the silver nano
function was
applied)
tE3
tE3
-
-
- This occurs when the duct condensing
temperature sensor is open.
- This occurs when the duct condensing
temperature sensor has a wire disconnected or is
short-circuited.
- The connector is out of place or has a contact
error.
Dry heater
temperature
sensor fault (for
models before
the silver nano
function was
applied)
Unbalance
Error
UE
UE
E4
dc
UE
- As laundry causes this error, check the laundry.
- Find the reason for the unbalance and solve it as
directed in the user manual.
Foaming
Detected
Sud
-
SUdS
-
- This occurs when too much foaming is detected.
It is also displayed while foaming is removed.
When the removal is finished, the normal cycle
proceeds. “Sud” or “SUdS” is displayed when too
much foaming is detected and “End” is displayed
when the removal of the foaming is finished.
(This is one of the normal operations. It is an error
for preventing non-sensing faults.)
Mems PBA
Error Detected
-
-
E8
-
- Error detected in the Mems PBA or data error
detected. Check the wire connections.
Replace if necessary.
1. Check the wire connections.
2. Replace the Mems PBA.
3. Main PBA wire connection error or PBA’s silver
nano part malfunction. Replace if necessary.
WF-M592NMH-YLP.indb 38
2010-2-22 13:29:58