Removal and Reassembly _ 25
Part
Figure
Description
DRAIN PUMP
6. Release the BAND RING (2EA) to remove
the HOSE (2EA).
7. Push the TUB inwards slightly to remove
the PUMP.
8. Disconnect the wires (2EA).
※
Check Points for Troubleshooting
1. Separate the Drain Filter and check if any alien substances are inside the pump (e.g.
coins, buttons .., etc.) → Remove these if found.
2. Check if the wire driving the pump is has come loose → Take the relevant countermeasure
if necessary.
3. When water leaks, check the assembly status of the Clamp Hose, and Cap Drain → Take
the relevant countermeasure if necessary.
Turn the filter counterclockwise to remove the remaining water.