ENGLISH-20
Connecting the cable
Power cable specifications
1 phase
Outdoor unit
Rated
Voltage Range
MCA
MFA
Hz
Volts
Min
Max
Min. Circuit Amps.
Max. Fuse Amps.
AE090RXEDEG
50
220-240
198
264
22 A
27.5 A
f
The power cable is not supplied with Air to Water Heat pump.
f
Supply cords of parts of appliances for outdoor use shall not be lighter than polychloroprene sheathed flexible cord (Code
designation IEC:60245 IEC 57 / CENELEC:H05RN-F)
f
This Equipment complies with IEC 61000-3-12.
3 Phase
Outdoor unit
Rated
Voltage Range
MCA
MFA
Hz
Volts
Min
Max
Min. Circuit Amps.
Max. Fuse Amps.
AE090RXEDGG
50
380-415
342
457
10 A
16.1 A
f
The power cable is not supplied with Air to Water Heat pump.
f
Supply cords of parts of appliances for outdoor use shall not be lighter than polychloroprene sheathed flexible cord (Code
designation IEC:60245 IEC 66 / CENELEC:H07RN-F)
f
This equipment complies with IEC 61000-3-12 provided that the short-circuit power Ssc is greater than or equal to
3.3[MVA] at the interface point between the user's supply and the public system. It is the responsibility of the installer or
user of the equipment to ensure, by consultation with distribution network operator if necessary, that the equipment is
connected only to a supply with a short-circuit power Ssc greater than or equal to 3.3[MVA].