Wiring Diagram
ACC2400C / ACC2800C
Cable Specifications
Rotary
Digital
Switch
Transmitter
(Optional)
Centralized
Controller
(Optional)
Sub PCB
Terminal block
Main PCB
208-230V~, 60Hz
208-230V~, 60Hz
Outdoor Unit
Indoor Unit
Wired
Remote
Controller
(Optional)
Ventilator
Motor
Communication
Power
EARTH
Float
Switch
SUB PCB
MAIN PCB
Receiver & Display Unit
(Optional)
DIP Switch
CN9
CN7
SW1
SW2
CN20 Connector
MAIN POWER
MAIN POWER
E-
42
Connecting the Connection Cord
The following electrical characteristics must be respected.
MODEL
Power
Sub switch
Fuse
Min. size of electric Wires
from/to the indoor/outdoor unit
Size of electric input wires
20m(6 ft) or less
50m(16 ft) or less
Note
1Ø - 208-230V~, 60Hz
ACC2800C
ACC2400C
30A
30A
25A
25A
AWG 17, 1.0mm
2
AWG 13, 2.5mm
2
AWG 11, 4.0mm
2
The power cables are not
supplied with the air conditioner.
The user should purchase them
separately.
3
8
9
16
ACC2400C IM_E<05381 2002.5.8 1:35 PM Page 42