How to Calculate the Quantity of Adding Refrigerant
The quantity of additional refrigerant is variable according to the installation situation . Thus, make sure the outdoor unit
situation before adding refrigerant . This operation can only be performed by a qualified refrigeration specialist .
Single installation outdoor unit
Model
Interconnection pipe length (m)
0~30
30~40
40~50
50~60
60~70
70~75
AC160JXAFKH
AC160JXAFNH
AC180JXA
✴
NH
AC200KXAPNH
AC250KXAPNH
0
+50g/m over 30m
DPM installation outdoor unit
Model
Diameter of L1, a
& b pipe
Installation condition
Amount of additional refrigerant charging
AC200KXAPNH
AC250KXAPNH
Φ 9 .52
L1 + . . . + Ln + 1 ≤ 75 m
Case 1 : L2 .L3,L4,L5 = Φ9 .52
(L1+a+b-5) x 35 [g] + (L2+ . . .+Ln+1) x 35 [g]
If (L1+a+b)< 5m, (L2+ . . .+Ln+1) x 35 [g]
Case 2 : L2 .L3,L4,L5 = Φ6 .35
(L1+a+b-5) x 35 [g] + (L2+ . . .+Ln+1) x 20 [g]
If (L1+a+b)< 5m, (L2+ . . .+Ln+1) x 20 [g]
❋
❋
"n" means the number of indoor unit connection of DPM .
Important information regulation regarding the refrigerant used
This product contains fluorinated greenhouse gases . Do not vent gases into the atmosphere .
•
Inform user if system contains 5 tCO₂e or more of fluorinated greenhouse gases . In this case, it has to be
checked for leakage at least once every 12 months, according to regulation n°517/2014 . This activity has to
be covered by qualified personnel only .
•
In case situation above (5 tCO₂e or more of R-410A), installer (or recognized person which has responsibility
for final check) has to provide a maintenance book, with all the information recorded according to
REGULATION (EU) No 517/2014 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 16 April 2014 on
fluorinated greenhouse gases .
CAUTION
Please fill in the following with indelible ink on the refrigerant charge label supplied
with this product and on this manual.
f
①
: The factory refrigerant charge of the product .
f
②
: The additional refrigerant amount charged in the field .
f
①
+
②
: The total refrigerant charge .
a . Factory refrigerant charge of the product: see unit name plate
b . Additional refrigerant amount charged in the field(Refer to the
above information for the quantity of refrigerant replenishment .)
c . Total refrigerant charge
d . Refrigerant cylinder and manifold for charging
NOTE
❋
❋
The filled-out label must be adhered in the proximity of the product
charging port (e .g . onto the inside of the stop valve cover) .
Refrigerant type
GWP value
R-410A
2088
❋
❋
GWP=Global Warming Potential
❋
❋
Calculating tCO₂e : kg x GWP / 1000
Indoor unit
d
②
①
Adding refrigerant (R-410A)
Unit
kg
tCO2e
①
, a
②, b
①+②
, C