31
English
Option setting
Status
13. Setting SEG16, SEG17 option
Press Low Fan button(
∨
) to enter SEG16 value.
Press High Fan button(
∧
) to enter SEG17 value.
Each time you press the button,
…
will be selected in rotation.
SEG16
SEG17
14. Advance to next “page”
Press Mode button to advance (“Dry”, “Off” on display)
15. Setting SEG18, SEG20 option
Press Low Fan button(
∨
) to enter SEG18 value.
Press High Fan button(
∧
) to enter SEG20 value.
Each time you press the button,
…
will be selected in rotation.
SEG18
SEG20
16. Advance to next “page”
Press Mode button to advance (“Fan”, “Off” on display)
17. Setting SEG21, SEG22 option
Press Low Fan button(
∨
) to enter SEG21 value.
Press High Fan button(
∧
) to enter SEG22 value.
Each time you press the button,
…
will be selected in rotation.
SEG21
SEG22
18. Advance to next “page”
Press Mode button to advance (“Heat”, “Off” on display)
19. Setting SEG23, SEG24 mode
Press Low Fan button(
∨
) to enter SEG23 value.
Press High Fan button(
∧
) to enter SEG24 value.
Each time you press the button,
…
will be selected in rotation.
SEG23
SEG24
Step 3. Check the option you have set
After setting option, press
button to view each “page” to verify the option code you input is correct.
Step 4. Input option
Press power button
two times while pointing the remote control at the indoor unit.
• When etering options this way, if you are only changing options after the system has been in operation, you mustgo
through all 20 option segments and set. If you do not, the controller will set unchaged segment to “0”. For example, if you
only change SEG17 to “1” and input the options into the indoor unit, all other 19 segments will be set to “0”.
NOTE
Step 5. Check operation
1) Reset the indoor unit by pressing the RESET button of indoor unit or outdoor unit.
2) Take the batteries out of the remote controller and insert them again and then press the operation button.