COMMISSION DELEGATED REGULATION (EU) No 626/2011

i)

 

PRODUCT FICHE (ENERGY LABELLING OF AIR CONDITIONERS)

ii)

A

Supplier's name

-

Samsung Electronics Co.. Ltd.

B

Model name (Indoor/Outdoor)

-

AC090MN4DKH / 

AC090MXADKH

AC090MNMDKH / 

AC090MXADKH

AC090MN4PKH / 

AC090MXADKH

AC090MNMDKH / 

AC090MXADNH

AC100MNCDKH / 

AC100MXADKH

C

Sound Power Level (Indoor/Outdoor)

dB(A)

60 / 68

58 / 68

60 / 68

58 / 68

60 / 69

D

Refrigerant name

1)

-

R-410A

R-410A

R-410A

R-410A

R-410A

E

GWP

-

2088

2088

2088

2088

2088

F

SEER

-

6.8

5.9

6.8

5.9

5.8

G

Energy efficiency class (SEER)

-

A++

A+

A++

A+

A+

H

Q

CE

2)

 (cooling season)

kWh/a

iii)

463

534

463

534

603

I

Pdesignc

kW

9.0 9.0 9.0 9.0 10.0 

J

SCOP (Average)

-

4.3

4.0

4.3

4.0

4.0

K

Energy efficiency class SCOP (Average)

-

A+

A+

A+

A+

A+

L

Q

HE

3)

 heating season (Average)

kWh/a

iii)

2051

1820

1726

1820

1820

M

Pdesignh (Average)

kW

6.3

5.2

5.3

5.2

5.2

N

Back up heating capacity(Average)

kW

0

0

0

0

0

O

Declared capacity (Average)

kW

6.3

5.2

5.3

5.2

5.2

P

Other heating seasons suitable for use

-

'-iv)

Q

SCOP (Warmer)

-

-

-

-

-

-

R

Energy efficiency class SCOP (Warmer)

-

-

-

-

-

-

S

Q

HE

3)

 heating season (Warmer)

kWh/a

iii)

-

-

-

-

-

T

Pdesignh (Warmer)

kW

-

-

-

-

-

U

Back up heating capacity (Warmer)

kW

-

-

-

-

-

V

Declared capacity (Warmer)

kW

-

-

-

-

-

W

SCOP (Colder)

-

-

-

-

-

-

X

Energy efficiency class SCOP (Colder)

-

-

-

-

-

-

Y

Q

HE

3)

 heating season (Colder)

kWh/a

iii)

-

-

-

-

-

Z

Pdesignh (Colder)

kW

-

-

-

-

-

AA

Back up heating capacity (Colder)

kW

-

-

-

-

-

AB

Declared capacity (Colder)

kW

-

-

-

-

-

Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would 
contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. 

This appliance contains a refrigerant fluid with a GWP equal to [2088]. This means that if 1 kg of this 
refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be [2088] times 
higher than 1 kg of CO

2

 , over a period of 100 years. 

Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always 
ask a professional.

Energy consumption “XYZ” kWh per year, based on standard test results. 

Actual energy consumption will depend on how the appliance is used and where it is located.

Energy consumption “XYZ” kWh per year, based on standard test results. Actual energy consumption will depend 
on how the appliance is used and where it is located.

Summary of Contents for AC090MXADKH

Page 1: ...conditioner Installation manual AC777MXAD7H AC777MXAS7H Thank you for purchasing this Samsung air conditioner Before operating this unit please read this manual carefully and retain it for future reference ...

Page 2: ...g air in the circuit 18 Step 9 Adding refrigerant R 410A 19 Step 10 Performing the gas leak test 22 Step 11 Connecting the drain hose to the outdoor unit 23 Step 12 Insulating the refrigerant pipes 23 Step 13 Checking the earthing 24 Step 14 Performing final check and trial operation 25 Extra procedures 28 Pumping down refrigerant 28 Relocating the indoor and outdoor units 28 Using the stop valve ...

Page 3: ...rom unauthorized changes or the improper connection of electric and requirements set forth in the Operating limits table included in the manual shall immediately invalidate the warranty The air conditioner should be used only for the applications for which it has been designed the indoor unit is not suitable to be installed in areas used for laundry Do not use the units if damaged If problems occu...

Page 4: ... maintenance operations to be carried out The unit s components should be accessible and easy to disassemble without endangering people and objects For this reason when provisions of the installation manual are not complied with the cost required to access and repair the units in SAFETY CONDITIONS as set out in prevailing regulations with harnesses ladders scaffolding or any other elevation system...

Page 5: ...s product is not provided by Samsung Indoor Unit Install the unit at a height where its base can be firmly fixed in place Make sure that the water dripping from the drain hose runs away correctly and safely CAUTION You have just purchased a system air conditioner and it has been installed by your installation specialist This device must be installed according to the national electrical rules If yo...

Page 6: ...r unit and apply a corrosion inhibitor on it At least once in a year Outdoor unit dimensions A Type AC090MXADKH AC090MXADNH AC100MXADKH AC100MXADNH AC120MXADKH AC120MXADNH AC120MXASEH 998 977 537 528 620 940 330 384 360 675 B Type AC140MXADKH AC140MXADNH 620 330 384 360 1210 1185 940 567 558 675 Minimum clearances for the outdoor unit When installing 1 outdoor unit Unit mm 300 or more 1500 or more...

Page 7: ...reachable and removable under safe conditions for people and the unit WARNING Should adopt bar type louver Don t use a type of rain resistance louver Bar type louver Rain resistance louver Louver specifications Angle criteria less than 20 Opening ratio criteria greater than 80 Moving the outdoor unit with wire rope 1 Before carrying the outdoor unit fasten two wire ropes of 8 m or longer as shown ...

Page 8: ...nstalling the outdoor unit on the roof waterproof the unit and check the ceiling strength Make sure that the wall can support the weights of the rack and the outdoor unit Install the rack close to the column as much as possible Optional Fixing the outdoor unit to a wall with a rack Soft rubber designed to cut off vibration from rack to wall not supplied with product Designed to cut off residual vi...

Page 9: ... conditioner to the earthing system before making the electrical connections NOTE Especially if your outdoor unit is the one designed for Russian and European markets consult the supply authority if necessary to estimate and reduce the supply system impedance before installation Air conditioning system examples When using earth leakage circuit breaker ELCB for a single phase MCCB 1 ELB Main power ...

Page 10: ...amp The unbalanced power must be maintained within 2 of supply rating If the power is unbalanced greatly it may shorten the life of the condenser If the unbalanced power is exceeded over 4 of supply rating the indoor unit is protected stopped and the error mode indicates To protect the product from water and possible shock you should keep the power cable and the connection cord of the indoor and o...

Page 11: ...240 198 264 24 0 24 0 1 5 25 5 25 5 30 0 AC120MNMDKH 50 220 to 240 198 264 24 0 24 0 2 5 26 5 26 5 30 0 AC120MNCDKH 50 220 to 240 198 264 24 0 24 0 2 0 26 0 26 0 30 0 AC120MNMSEH AC120MXASEH 50 220 to 240 198 264 24 0 24 0 3 5 27 5 27 5 30 0 AC140MN4DKH AC140MXADKH 50 220 to 240 198 264 32 0 32 0 1 0 33 0 33 0 40 0 AC140MN4PKH 50 220 to 240 198 264 32 0 32 0 1 5 33 5 33 5 40 0 AC140MNMDKH 50 220 t...

Page 12: ...12 provided that the short circuit power Ssc is greater than or equal to Ssc 2 at the interface point between the user s supply and the public system It is the responsibility of the installer or user of the equipment to ensure by consultation with the distribution network operator if necessary that the equipment is connected only to a supply with a short circuit power Ssc greater than or equal to ...

Page 13: ...essed ring terminal Cover a solderless ring terminal and a connector part of the power cable and then connect it Silver solder Nominal dimensions for cable mm Nominal dimensions for screw mm B D d1 E F L d2 t Standard dimension mm Allowance mm Standard dimension mm Allowance mm Standard dimension mm Allowance mm Min mm Min mm Max mm Standard dimension mm Allowance mm Min mm 4 6 4 9 5 0 2 5 6 0 3 0...

Page 14: ...ve the Plate bottom Outdoor to indoor power and communication cables specifications Indoor power supply Power supply Max Min V Indoor power cable 1ø 220 240V 50 Hz 10 1 5 mm Ĺ 3 wires Communication cable 0 75 to 1 5 mm 2 wires Power supply cords of parts of appliances for outdoor use shall not be lighter than polychloroprene sheathed flexible cord Code designation IEC 60245 IEC 57 CENELEC H05RN F ...

Page 15: ...ith the insulation tape twice or more and position your contraction tube in the middle of the insulation tape Three or more layers of insulation are required Method 1 Method 2 Insulation tape 40 mm 35 mm Insulation tape 6 Apply heat to the contraction tube to contract it Contraction tube 7 After tube contraction work is completed wrap it with the insulation tape to finish Insulation tape CAUTION M...

Page 16: ... 30 m 30 m 30 m 30 m Max height difference among indoor units h2 0 5 m 0 5 m Max Pipe length difference among indoor units after branch L2 L3 or L2 L4 or L2 L5 or a b or a L2 b L4 or a L3 b L5 5 m 5 m n means the number of indoor unit connection of DPM indoor indoor indoor outdoor outdoor outdoor indoor indoor indoor indoor indoor indoor indoor outdoor L1 L1 L2 L2 D D D D h2 h2 L3 L3 L4 L4 L5 L1 a...

Page 17: ... care to ensure that the cut edge remains at a 90 angle with the side of the pipe Refer to the illustrations below for examples of edges cut correctly and incorrectly Pipe cutter Pipe 90 Oblique Rough Burr 90 3 To prevent any gas from leaking out remove all burrs at the cut edge of the pipe using a reamer 4 Slide a flare nut on to the pipe and modify the flare D A D 4 5 2 90 2 Pipe Flare Flare R 0...

Page 18: ...n recovering the refrigerant ground the compressor first before removing the connection pipe If the refrigerant pipe is not properly connected and the compressor works with the service valve open the pipe inhales the air and it makes the pressure inside of the refrigerant cycle abnormally high It may cause explosion and injury The air in the indoor unit and in the pipe must be evacuated If air rem...

Page 19: ...and deoxidized copper pipe Cu DHP type to ISO 1337 or UNI EN 12735 1 suitable for operating pressures of at least 4200 kPa and for a burst pressure of at least 20700 kPa Copper pipe for hydro sanitary applications is completely unsuitable For sizing and limits height difference line length max bends refrigerant charge etc see Connecting refrigerant pipe section Step 9 Adding refrigerant R 410A The...

Page 20: ... Outdoor Unit Unit kg tCO2e a b c Refrigerant type GWP value R 410A 2088 GWP Global Warming Potential Calculating tCO2e kg x GWP 1000 NOTE a Factory refrigerant charge of the product see unit name plate b Additional refrigerant amount charged in the field Refer to the above information for the quantity of refrigerant replenishment c Total refrigerant charge d Refrigerant cylinder and manifold for ...

Page 21: ...PM Please refer to the table below DPM KIT 2 Indoor units connection 3 Indoor units connection 4 Indoor units connection MXJ 2D2509K MXJ 3D2509K MXJ 4D2509K Connecting communication line and wired remote controller In case of 2 indoor units connection F1 F2 F1 F2 F1 F2 L N L N L N Outdoor unit Remote control Indoor unit 1 Indoor unit 2 In case of 3 indoor units connection Outdoor unit Remote contr...

Page 22: ...tch twice and check A2 sign on 7 segment If there are three indoor units press K2 switch three times and check A3 sign on 7 segment If there are four indoor units press K2 switch four times and check A4 sign on 7 segment Press K1 switch to complete setting the number of the installed indoor unit Check AA sign on 7 segment Step 10 Performing the gas leak test LEAK TEST WITH NITROGEN before opening ...

Page 23: ...egion of heavy snow allow enough separation distance between the product and the ground Step 12 Insulating the refrigerant pipes Once you have checked that there are no leaks in the system you can insulate the piping and hose 1 To avoid condensation problems place an insulator around each refrigerant pipe No gap NBR NOTE When insulate the pipe be sure to overlap the insulation The insulation has t...

Page 24: ...ave a earthing or the earthing does not comply with specifications an earthing electrode must be installed The corresponding accessories are not supplied with the air conditioner 1 Select an earthing electrode that complies with the specifications given in the illustration 2 Connect the flexible hose to the flexible hose port In damp hard soil rather than loose sandy or gravel soil that has a high...

Page 25: ...door unit PCB to run the test mode and stop Key Push type Mode Display SEG 1 SEG 2 SEG 3 SEG 4 K1 Short 1st Heating test mode 2nd Defrost test mode 3rd Stop K2 Short 1st Cooling test 2nd Inverter check 3rd Pump down K3 Short 1st Reset Release Eco mode Defrost test mode Condition 1 The outdoor temperature is below 10 C Condition 2 All the temperature conditions should meet the defrost conditions K1...

Page 26: ... digit Tens digit rpm 10 Target discharge temperature A Hundreds digit Tens digit Units digit C 11 EEV B Hundreds digit Tens digit Units digit step 12 The capacity sum of indoor units C Tens digit Unit digit The first place of decimals kW 13 Protective control D 0 Cooling 1 Heating Protective control 0 No Protective control 1 Freezing 2 Non stop defrosting 3 Over load 4 Discharge 5 Total electric ...

Page 27: ...e Option mode when the air conditioner is running Set the address in SEG3 and SEG4 by pressing the K2 switch shortly Option SEG1 SEG2 SEG3 SEG4 Function Channel address 0 0 A U The address is setautomatically 00 to 15 The address is setmanually You can set avalue from 0 to 15 Press and hold the K2 switch for a while to save the address and exit the Option mode Each segment will flicker for 3 secon...

Page 28: ... refrigerant pipe in order to avoid refrigerant loss to the atmosphere 2 Release the valve caps on High and Low pressure side 3 Use L wrench to close the valve on the high pressure side 4 After approximately 2 minute close the valve on the low pressure side 5 Stop operation of the air conditioner by pressing the Power button on the indoor unit or remote control 6 Disconnect the pipes B liquid A Ga...

Page 29: ... to 35 Over Ø19 05 35 to 40 1 N m 10 kgf cm NOTE Do not apply excessive force to the stop valve and always use special instruments Otherwise the stopping box can be damaged and the back sheet can leaks If the watertight sheet leaks turn the axis back by half tighten the stopping box then check the leakage again If there is no leakage any more tighten the axis entirely Closing the stop valve 1 Remo...

Page 30: ...eted Check electrical connection and setting between indoor unit and outdoor unit 10 E203 Communication error between the outdoor unit and main micom For PF 4 to 6 controllers error will be determined from the time when the compressor is turned on Check electrical connection and setting between outdoor unit MAIN PBA INVERTER PBA 11 E221 Error on outdoor temperature sensor Short or Open Check Outdo...

Page 31: ...5 E473 Comp Lock error 36 E474 Error on IPM Heat Sink sensor of inverter 1 Short or Open Check Outdoor Inverter PBA 37 E475 Error on inverter fan 2 FAN2 ERROR 38 E484 PFC Overload Over current Error Check Outdoor Inverter PBA 39 E485 Error on input current sensor of inverter 1 Short or Open Check Outdoor EEPROM PBA 40 E500 IPM over heat error on inverter 1 Check Outdoor Inverter PBA 41 E508 Smart ...

Page 32: ...mer S QHE 3 heating season Warmer kWh aiii T Pdesignh Warmer kW U Back up heating capacity Warmer kW V Declared capacity Warmer kW W SCOP Colder X Energy efficiency class SCOP Colder Y QHE 3 heating season Colder kWh aiii Z Pdesignh Colder kW AA Back up heating capacity Colder kW AB Declared capacity Colder kW 1 Refrigerant leakage contributes to climate change Refrigerant with lower global warmin...

Page 33: ...r R Energy efficiency class SCOP Warmer S QHE 3 heating season Warmer kWh aiii T Pdesignh Warmer kW U Back up heating capacity Warmer kW V Declared capacity Warmer kW W SCOP Colder X Energy efficiency class SCOP Colder Y QHE 3 heating season Colder kWh aiii Z Pdesignh Colder kW AA Back up heating capacity Colder kW AB Declared capacity Colder kW 1 Refrigerant leakage contributes to climate change ...

Page 34: ...Warmer R Energy efficiency class SCOP Warmer S QHE 3 heating season Warmer kWh aiii T Pdesignh Warmer kW U Back up heating capacity Warmer kW V Declared capacity Warmer kW W SCOP Colder X Energy efficiency class SCOP Colder Y QHE 3 heating season Colder kWh aiii Z Pdesignh Colder kW AA Back up heating capacity Colder kW AB Declared capacity Colder kW 1 Refrigerant leakage contributes to climate ch...

Page 35: ...er R Energy efficiency class SCOP Warmer S QHE 3 heating season Warmer kWh aiii T Pdesignh Warmer kW U Back up heating capacity Warmer kW V Declared capacity Warmer kW W SCOP Colder X Energy efficiency class SCOP Colder Y QHE 3 heating season Colder kWh aiii Z Pdesignh Colder kW AA Back up heating capacity Colder kW AB Declared capacity Colder kW 1 Refrigerant leakage contributes to climate change...

Page 36: ...y efficiency class SCOP Melegebb Classe de eficiência energética SCOP Mais quente S QHE 3 temporada calefacción Más cálida QHE 3 saison chaude plus chaude QHE 3 altre stagioni d uso Melegebb QHE 3 estação de aquecimento Mais quente T Pdesignh Más cálida Pdesignh plus chaude Pdesignh Melegebb Pdesignh Mais quente U Copia de seguridad de capacidad de calefacción Más cálida Sauvegarder la capacité de...

Page 37: ... 6 23 ȝȑıȘ İʌȠȤȒ Enegie efficiencyklasse SCOP warmer Klasa energetyczna SCOP cieplej S QHE 3 Heizperiode wärmer QHE İʌȠȤȒ șȑȡȝĮȞıȘȢ ȝȑıȘ İʌȠȤȒ QHE 3 verwarmingsseizoen warmer QHE 3 okres grzewczy cieplej T Pdesignh wärmer 3GHVLJQK șİȡȝȩIJİȡȘ İʌȠȤȒ Pdesignh warmer Deklarowane obciążenie grzewcze cieplej U Sichern Heizleistung wärmer ǻȘȝȚȠȣȡȖȓĮ ĮȞIJȚȖȡȐijȦȞ ĮıijĮȜİȓĮȢ ȚțĮȞȩIJȘIJĮ șȑȡȝĮȞıȘȢ șİȡȝȩIJİȡȘ İʌȠȤȒ...

Page 38: ...nergetické účinnosti SCOP teplejší Trieda energetickej účinnosti SCOP Teplejšia Clasă de eficiență energetică SCOP mai cald S QHE 3 fűtési szezon melegebb QHE 3 období topení teplejší QHE 3 sezóna vykurovania Teplejšia QHE 3 perioadă de încălzire mai cald T Pdesignh melegebb Pdesignh teplejší Pdesignh Teplejšia Pdesignh mai cald U Biztonsági fűtőteljesítmény melegebb Záložní topný výkon teplejší Z...

Page 39: ...šia SCOP varmere R Ʉɥɚɫ ɧɚ ɟɧɟɪɝɢɣɧɚ ɟɮɟɤɬɢɜɧɨɫɬ 6 23 ɩɨ ɬɨɩɥɨ Razred energetske učinkovitosti SCOP Toplije Trieda energetickej účinnosti SCOP Teplejšia Energieffektivitetsklasse SCOP varmere S QHE ɫɟɡɨɧ ɧɚ ɨɬɨɩɥɟɧɢɟ ɩɨ ɬɨɩɥɨ QHE 3 sezona grijanja Toplije QHE 3 sezóna vykurovania Teplejšia QHE 3 varmesæson varmere T Ɉɛɹɜɟɧ ɨɬɨɩɥɢɬɟɥɟɧ ɬɨɜɚɪ ɩɨ ɬɨɩɥɨ Pdesignh Toplije Pdesignh Teplejšia Pdesignh var...

Page 40: ... varmare SCOP lämmin SCOP soojem SCOP siltākā R Energieffektivitetsklass SCOP varmare Energiatehokkuusluokka SCOP lämmin Energiatõhususe klass SCOP soojem Energoefektivitātes klase SCOP siltākā S QHE 3 uppvärmningssäsong varmare QHE 3 lämmityskausi lämmin QHE 3 kütmishooaeg soojem QHE 3 sildīšanas sezonā siltākā T Pdesignh varmare Pdesignh lämmin Pdesignh soojem Deklarētā sildīšanas slodze siltākā...

Page 41: ...as ODVD HQHUJHWVNH HILNDVQRVWL 6 23 7RSOLML GHR JRGLQH S QHE 3 šildymo sezonas šiltesnis klimatas QHE JUHMQD VH RQD 7RSOLML GHR JRGLQH T Projektinė apkrova šildymo režimu Pdesignh šiltesnis klimatas 3GHVLJQK 7RSOLML GHR JRGLQH U Atsarginis šildymo pajėgumas šiltesnis klimatas Ȼɚɰɤ ɭɩ ɤɚɩɚɰɢɬɟɬ ɝɪɟʁɚʃɚ 7RSOLML GHR JRGLQH V Projektinis pajėgumas šiltesnis klimatas HNODULVDQL NDSDFLWHW 7RSOLML GHR JR...

Page 42: ...La consommation d énergie réelle dépend des conditions d utilisation et de l emplacement de l appareil ITALIANO IT 1 La perdita di refrigerante contribuisce al cambiamento climatico In caso di rilascio nell atmosfera i refrigeranti con un potenziale di riscaldamento globale GWP più basso contribuiscono in misura minore al riscaldamento globale rispetto a quelli con un GWP più elevato Questo appare...

Page 43: ...en bij tot de klimaatveranderingen Koelmiddelen met een lager Global Warming Potential GWP dragen minder bij tot de klimaatveranderingen dan een koelmiddel met een hogere GWP indien ze in de atmosfeer vrijkomen Dit apparaat bevat een koelmiddel met een GWP van 2088 Dit betekent dat als 1 kg van deze koelvloeistof in de atmosfeer zou lekken de invloed hiervan op de klimaatveranderingen 2088 keer zo...

Page 44: ...energie závisí na způsobu používání a umístění zařízení SLOVENČINA SK 1 Úniky chladiva prispievajú k zmene klímy Chladivo s nižším potenciálom prispievania ku globálnemu otepľovaniu GWP by pri úniku do atmosféry prispelo ku globálnemu otepľovaniu v nižšej miere ako chladivo s vyšším GWP Toto zariadenie obsahuje chladiacu kvapalinu s GWP rovnajúcim sa 2088 Znamená to že ak by do atmosféry unikol 1 ...

Page 45: ...orabe uređaja i o mjestu na kojem se nalazi 3 Potrošnja energije XYZ kWh na godinu na temelju rezultata standardnih ispitivanja Stvarna potrošnja energije ovisi o načinu uporabe uređaja i o mjestu na kojem se nalazi SLOVENČINA SL 1 Úniky chladiva prispievajú k zmene klímy Chladivo s nižším potenciálom prispievania ku globálnemu otepľovaniu GWP by pri úniku do atmosféry prispelo ku globálnemu otepľ...

Page 46: ... tarkoittaa että jos yksi kilo tätä kylmäainetta pääsisi ilmakehään sen vaikutus ilmaston lämpenemiseen olisi 2088 kertaa suurempi kuin yhdellä kilolla hiilidioksidia 100 vuoden ajanjaksolla Älä koskaan yritä kajota kylmäainepiiriin tai purkaa tuotetta omin päin vaan pyydä aina ammattilaisen apua 2 Energiankulutus XYZ kWh vuodessa laskettuna vakio olosuhteissa Tosiasiallinen energiankulutus riippu...

Page 47: ...ui būtų 2088 kartus didesnė nei patekus 1 kg CO2 per 100 metų laikotarpį Niekada nebandykite patys taisyti šaldymo grandinės arba ardyti gaminio visada prašykite kad tai atliktų specialistas 2 XYZ kWh energijos suvartojimo per metus duomenys pagrįsti standartinio bandymo rezultatais Faktinis energijos suvartojimas priklauso nuo to kaip prietaisas naudojamas ir kokioje vietoje jis yra 3 XYZ kWh ene...

Page 48: ...SUNG ELECTRONICS CO LTD SGEC 107 Hanamsandan 6beon ro Gwangsan gu Gwangju si Korea 62218 Samsung Electronics UK Ltd Euro QA Lab Blackbushe Business Park SaxonyWay Yateley Hampshire GU46 6GG United Kingdom ...

Reviews: