48
1. Prepare the following tools.
Tools
Crimping pliers
Connection sleeve
Insulation tape
Contraction tube
Spec
MH-14
20xØ0.26 inch(6.5 mm)
(HxOD)
Width 0.75 inch(19 mm)
70xØ0.31 inch(8.0 mm)
(LxOD)
Shape
2. As shown in the figure, peel off the shields from the rubber and wire of the
power cable.
- Peel off 0.79 inch(20 mm) of cable shields from the pre-installed tube.
t
For information about the power cable specifications for indoor and
outdoor units, refer to the installation manual.
t
After peeling off cable wires from the pre-installed tube, insert a
contraction tube.
CAUTION
Unit: inch(mm)
120
60
20
20
20
180
Power cable
20
Pre-installed tube for the power cable
0.79 (20)
0.79 (20)
0.79 (20)
2.36 (60)
4.72 (120)
7.09 (180)
0.79 (20)
3. Insert both sides of core wire of the power cable into the connection sleeve.
f
Method 1
Push the core wire into the sleeve from both sides.
Connection sleeve
f
Method 2
Twist the wire cores together and push it into the sleeve.
Connection sleeve
4. Using a crimping tool, compress the two points and flip it over and compress another two points in the same location.
- The compression dimension should be 0.31 inch (8.0 mm).
- After compressing it, pull both sides of the wire to make sure it is firmly pressed.
Compression
dimension
f
Method 1
Compress it 4 times.
0.20 inch
(5 mm)
f
Method 2
Compress it 4 times.
0.20 inch
(5 mm)
Extending the power cable