When installing more than 1 outdoor unit
15
00
o
r m
or
e
(Unit : mm)
❋
❋
When the air outlet is towards the wall
30
0
or
m
or
e
300 or more
600 or more
600 or more
600 or more
❋
❋
When 3 sides of the outdoor unit are blocked by the wall
30
0
or
m
or
e
15
00
o
r m
or
e
600 or more
600 or more
❋
❋
When front and rear side of the outdoor unit is towards the wall
❋
❋
The upper part of the outdoor unit and
the air outlet is towards the wall
1500 or more
600 or more
3000 or more
300 or more
3000 or more
❋
❋
When front and rear side of the outdoor unit is towards the wall
• The units must be installed according to distances declared, in order to permit accessibility from each side,
either to guarantee correct operation of maintenance or repairing products .
The unit’s parts must be reachable and removable completely under safety condition (for people or things) .