A failure to comply with the requirements for storing the pump may result in internal
damage to the device
If the temperature is below freezing point of the water, it could damage the pump.
Under these conditions, the pump must be drained completely
All plugs and protective covers must be fitted during storage
2.5 Pump storage and draining procedure
The pump’s water is drained on delivery, and the pump can be immediately stored in accordance with the
technical specifications.
After operation, the pump can be stored for 30 days without further action.
If the pump remains out of operation for a longer period of time after use, its water must be drained, and
the water supply to the pump must be shut off.
When emptying the pump, it is important that all chambers inside the pump are emptied.
To empty the correct chambers (X) depends on the rotation of the pump (CW or CCW). See table below.
The pump can be fitted with valves in the draining connections. See below.
Chamber
Rotation
A
B
C
1
or C
2
D
1
or
D
2
or
D
3
or
D
4
CW
X
X
X
CCW
X
X
X
Draining during normal operation, see chapter 5.