5

Designing an Installation Plan

If you are a professional installer, you’ll probably want 

to skip over this section, however if you are setting 

up your system for the first time, this section can help 

make your installation a little bit easier.
Before you start plugging, stripping and connecting 

wires, it a good idea to have a clear installation plan. To 

create your installation plan, you need to consider sev-

eral design parameters including what sound sources 

will be used, if announcement paging in necessary, 

which rooms need to have sound, if remote volume 

control is required, which type of speakers will do the 

best job for the room they are covering, and your wir-

ing plan.  

Selecting the Sound Sources

If you are using multiple sound sources, you'll need 

some type of mixer and for fixed installations, a zone 

mixer like the Samson S zone is ideal. The S zone 

provides four input channels with the ability to con-

nect up to six input sources.  On input Channel’s 1 and 

2 there is an input for connecting microphones with 

phantom power to operate condenser type mics. The 

S zone also has a special Ducking feature so when you 

speak into the microphone, the volume of the music 

is automatically lowered. You can connect line level 

signals on all four input channels, so signals from TAPE, 

CD, DVD or Karaoke players, Audio/Video TV monitors, 

Radio Tuners, DJ mixers or any other line level device 

can be used as a sound source. You may also be able 

to connect the output from a home hi-fi receiver if it’s 

equipped with a line level output. For example, in a 

small to medium size restaurant, you may want back-

ground music from a CD in one room, Disco Karaoke 

in another room, the ability to have a hostess paging 

parties for their tables and a cook paging a waitress to 

pick up an order. The Samson S zone can accomplish 

all of this easily.

Creating the Audio Zones

You can create separate audio environments using up 

to four S zone’s outputs, each connected to the input 

on the SZ series amplifier. You can connect one or 

more speakers with a total load impedance of 4 ohms 

or more to the SZ Series amplifier's output.  Obviously, 

(or perhaps not so obviously) we call an output a zone 

on the S zone, but a zone is also the area where you 

want to have sound. So, think about where you want 

to distribute the sound.  The SZ Series amplifiers and S 

zone can accomplish all of this easily. In addition, the 

S zone let’s you easily connect a remote control level 

for each of the zones, so you can control the volume 

in the room even if the audio equipment is located 

somewhere else.

Designing an Installation Plan

Summary of Contents for POWER AMPLIFERS SZ1120

Page 1: ...POWER POWER POWER SZ1120 SZ1240 SZ1360 POWER AMPLIFERS SZ SERIES...

Page 2: ...NG TYPE PLUG POLARIZED PLUG HAS TWO BLADES WITH ONE WIDER THAN THE OTHER GROUNDING TYPE PLUG HAS TWO BLADES AND A THIRD GROUNDING PRONG 4HE WIDE BLADE OR THE THIRD PRONG ARE PROVIDED FOR YOUR SAFETY F...

Page 3: ...or objects have fallen into the unit the unit has been exposed to rain or moisture does not operate normally or has been dropped PRECAUCION Para reducir el riesgo de incendios o descargas no permita q...

Page 4: ...h com Table of Contents Introduction 1 SZ Series Features 2 SZ Series Layout Front Panel 3 SZ Series Layout Rear Panel 4 Designing an Installation Plan 5 Setting Up and Using Your SZ Series 8 The SZ S...

Page 5: ...teel chassis 19 inch rack mount design and convenient carry handles facilitating easy installation in any rack Optimized for commercial installations including schools houses of worship office buildin...

Page 6: ...d frequency response of 70Hz to 18kHz guarantee ultra clean sound quality LED signal indicators continuously display power output levels and allow you to correct for overloading clipping conditions Fo...

Page 7: ...ED to fade slowly when the amp is powered off When lit no signal is provided to any connected speakers thus muting them and preventing any thump from occurring For a complete description of the condit...

Page 8: ...iring and interconnection instructions 5 LEVEL ADJUST This control knob provides input level adjustment from 12dB to 0dB 6 HPF HIGH PASS FILTER Selectable High Pass or low cut filter at 400Hz used whe...

Page 9: ...owered You can connect line level signals on all four input channels so signals from TAPE CD DVD or Karaoke players Audio Video TV monitors Radio Tuners DJ mixers or any other line level device can be...

Page 10: ...no liability for any installation Designing an Installation Plan Now take some time to consider where you need to have sound in your particular installation After you have decided where you need to cr...

Page 11: ...so adjust some speakers to different output levels see diagram below The SZ Series amplifiers have built in transformers that step up the output voltage and reduce the current allowing you to connect...

Page 12: ...placed it can be used free standing or mounted in a standard 19 rack requiring only two rack spaces When installed make sure that both the front and rear panels are unobstructed and that there is good...

Page 13: ...ent conditions This occurs whenever the signal being output from the SZ Series rises to a level above 20 THD Total Harmonic Distortion Shorted speaker cables This will occur if due to faulty wiring th...

Page 14: ...4 ohm 8 ohm and 70 Volt operation SZ Series Connections 8 Ohm Operation One 8 Ohm speaker per amplifer 8 Ohm 8 Ohm 4 Ohm 4 Ohm 4 Ohm Operation Two 8 Ohm speakers per amplifer 70 Volt Operation Four sp...

Page 15: ...and music The first two SZ amps are connected to four wall mounted speakers in each of the Dining Rooms with their transformers set to a 25 watt tap The third SZ amp powers two speakers in the outside...

Page 16: ...tion Signal Ground 1 3 2 2 3 1 Hot Cold Female XLR Male XLR Hot 2 Cold 3 Common 1 Common Hot Cold Hot 2 Cold 3 Common 1 Common Solder Points End View End View Solder Points 1 2 3 2 1 3 SZ Series Input...

Page 17: ...LECTRICAL SHOCK DO NOT HOLD OR TOUCH THE COMMON AND 70 OR 100 VOLT WIRE CONNECTION WHILE OPERATING THE AMPLIFIER 25 Volt Wiring Guide Follow the guidelines below to select the appropriate size wire ba...

Page 18: ...T H D at 1 2 rated output 1kHz Less than 1 0 Cooling Variable speed fan Operating Temperature Humidity 0 40 C at 95 non condensing Power Consumptions at full power SZ1120 185W SZ1240 361W SZ1360 525W...

Page 19: ...15 Block Diagram...

Page 20: ...Samson Technologies Corp 45 Gilpin Avenue Hauppauge New York 11788 8816 Phone 1 800 3 SAMSON 1 800 372 6766 Fax 631 784 2201 www samsontech com...