Samson POWER AMPLIFERS SZ1120 Owner'S Manual Download Page 10

6

Using Active Speakers

In a larger installation, you may use a combination of 

passive speakers connected to your SZ Series amplifier 

along with some active, or self powered speakers in a 

different zone. When using active speakers, you can 

connect the S zone’s outputs using the balanced line 

level signals. In this case, you will run line level signal 

from the S zone’s Zone Output over the long wire 

run to the input of the powered speaker located in 

the sound zone. For more information on wiring for 

balanced signals, see the Input Wiring Guide on page 

12 of this manual. 

Using Passive Speakers

If you are using passive (un-powered) speakers, you 

need to first decide where you will place your power 

amplifier. If the speakers in a particular sound zone are 

less than 100 feet away, you can locate your SZ series 

power amplifier in the same rack as the S zone and 

connect the speaker wires from the amplifier to your 

sound zone.

 

NOTE: This type of wiring is known as "home-run wiring" 

since you are making direct connections from the 

amplifiers in the equipment rack to the speakers located 

in the sound zone room. 

In this case, you would connect the S zone’s Zone 

Output to the SZ Series Input and then run the speaker 

wires to the passive speakers. Be sure to check the 

impedance of the speakers you are using. SZ Series 

amplifiers can run at 4 ohms, so connect one 4 ohm or 

two 8 ohm speakers on each SZ output channel. If the 

speakers in a particular sound zone are further than 

100 feet, you should consider placing the amplifier in 

the same room as the sound zone or use a constant 

voltage speaker system. 

Using A Constant Voltage Speaker System

If your installation requires multiple speakers and 
long cable runs, you should consider running a 70 volt, 
constant voltage system. Constant voltage systems 
became the installation standard in the mid-1900’s 
offering a cost effective solution for installations using 
multiple speakers and long cable runs.  The idea was 
borrowed from the cross-country power grid where 
voltage is stepped up and therefore the current is 
reduced allowing huge amounts of power to run over 
long distances on relatively small, lower cost cable. 
Ultimately the voltage is stepped down and delivered 
to the customer over a short, heavy gauge cable. 

IMPORTANT NOTE:

 

Only licensed and insured 

professional sound contractors should install Constant 

Voltage Systems. Samson assumes no liability for any 

installation. 

Designing an Installation Plan

Now, take some time to consider where you need to 

have sound in your particular installation. After you 

have decided where you need to create sound zones, 

you can consider your speaker selection, but first 

decide where you are going to locate your equipment 

rack.

Locating Your Equipment Rack

Since the SZ series amplifers and S zone are standard 

19-inch rack mount devices, you should consider using 

an equipment rack, such as one of the Samson SRK 

series. To select a good location for your equipment 

rack, you should consider several points including 

the proximity to each of the sound zones, if the users 

need to access the gear to change CD’s or to adjust a 

volume level and if you have a convenient location to 

the electrical service, to name a few. You will need to 

consider the length of wire runs and routing necessary 

to make the connections from the equipment rack to 

the various sound zones. Depending on the speakers 

you choose, and the length of cable runs you need 

to make, you may choose to run speaker level or line 

level to the sound zones. If you are using passive 

(non-powered) speakers, you will need to connect 

the output channels of the S zone to an input channel 

of the SZ amplifier and run speaker wire, however 

you need to be careful to pay attention to the wire 

gauge and total length of the wire run. If you are 

using powered (active) speakers, you can run long 

distances using the balanced outputs directly from the 

S zone. Since the SZ Series' and S zone's inputs and 

output connections are terminated using Euroblock 

connectors, the wiring can easily be run in advance of 

the equipment installation.
Another type of installation is one that uses speakers 

and amplifiers (like the SZ Series) with 70-volt 

transformers, which are commonly referred to as 

Constant Voltage systems. The benefit of a Constant 

Voltage system is you can run long lengths of wire and 

have many speakers connected to a single amplifier. 

You can also balance the level of each speaker by using 

one of the available transformer settings. The SZ series 

amplifiers are ideal for this thanks to their built-in 

25/70/100 volt output transformers. 

Selecting Speakers for Each Zone

To select the speakers, you need to consider a few 

important issues, like where you are going to place 

your power amplifiers, using powered or un-powered 

speakers, or if you need to run a 70-volt distributed 

sound system. The following sections provide a brief 

overview on how to connect active and passive 

speakers or a constant voltage system in a typical 

installation. 

Summary of Contents for POWER AMPLIFERS SZ1120

Page 1: ...POWER POWER POWER SZ1120 SZ1240 SZ1360 POWER AMPLIFERS SZ SERIES...

Page 2: ...NG TYPE PLUG POLARIZED PLUG HAS TWO BLADES WITH ONE WIDER THAN THE OTHER GROUNDING TYPE PLUG HAS TWO BLADES AND A THIRD GROUNDING PRONG 4HE WIDE BLADE OR THE THIRD PRONG ARE PROVIDED FOR YOUR SAFETY F...

Page 3: ...or objects have fallen into the unit the unit has been exposed to rain or moisture does not operate normally or has been dropped PRECAUCION Para reducir el riesgo de incendios o descargas no permita q...

Page 4: ...h com Table of Contents Introduction 1 SZ Series Features 2 SZ Series Layout Front Panel 3 SZ Series Layout Rear Panel 4 Designing an Installation Plan 5 Setting Up and Using Your SZ Series 8 The SZ S...

Page 5: ...teel chassis 19 inch rack mount design and convenient carry handles facilitating easy installation in any rack Optimized for commercial installations including schools houses of worship office buildin...

Page 6: ...d frequency response of 70Hz to 18kHz guarantee ultra clean sound quality LED signal indicators continuously display power output levels and allow you to correct for overloading clipping conditions Fo...

Page 7: ...ED to fade slowly when the amp is powered off When lit no signal is provided to any connected speakers thus muting them and preventing any thump from occurring For a complete description of the condit...

Page 8: ...iring and interconnection instructions 5 LEVEL ADJUST This control knob provides input level adjustment from 12dB to 0dB 6 HPF HIGH PASS FILTER Selectable High Pass or low cut filter at 400Hz used whe...

Page 9: ...owered You can connect line level signals on all four input channels so signals from TAPE CD DVD or Karaoke players Audio Video TV monitors Radio Tuners DJ mixers or any other line level device can be...

Page 10: ...no liability for any installation Designing an Installation Plan Now take some time to consider where you need to have sound in your particular installation After you have decided where you need to cr...

Page 11: ...so adjust some speakers to different output levels see diagram below The SZ Series amplifiers have built in transformers that step up the output voltage and reduce the current allowing you to connect...

Page 12: ...placed it can be used free standing or mounted in a standard 19 rack requiring only two rack spaces When installed make sure that both the front and rear panels are unobstructed and that there is good...

Page 13: ...ent conditions This occurs whenever the signal being output from the SZ Series rises to a level above 20 THD Total Harmonic Distortion Shorted speaker cables This will occur if due to faulty wiring th...

Page 14: ...4 ohm 8 ohm and 70 Volt operation SZ Series Connections 8 Ohm Operation One 8 Ohm speaker per amplifer 8 Ohm 8 Ohm 4 Ohm 4 Ohm 4 Ohm Operation Two 8 Ohm speakers per amplifer 70 Volt Operation Four sp...

Page 15: ...and music The first two SZ amps are connected to four wall mounted speakers in each of the Dining Rooms with their transformers set to a 25 watt tap The third SZ amp powers two speakers in the outside...

Page 16: ...tion Signal Ground 1 3 2 2 3 1 Hot Cold Female XLR Male XLR Hot 2 Cold 3 Common 1 Common Hot Cold Hot 2 Cold 3 Common 1 Common Solder Points End View End View Solder Points 1 2 3 2 1 3 SZ Series Input...

Page 17: ...LECTRICAL SHOCK DO NOT HOLD OR TOUCH THE COMMON AND 70 OR 100 VOLT WIRE CONNECTION WHILE OPERATING THE AMPLIFIER 25 Volt Wiring Guide Follow the guidelines below to select the appropriate size wire ba...

Page 18: ...T H D at 1 2 rated output 1kHz Less than 1 0 Cooling Variable speed fan Operating Temperature Humidity 0 40 C at 95 non condensing Power Consumptions at full power SZ1120 185W SZ1240 361W SZ1360 525W...

Page 19: ...15 Block Diagram...

Page 20: ...Samson Technologies Corp 45 Gilpin Avenue Hauppauge New York 11788 8816 Phone 1 800 3 SAMSON 1 800 372 6766 Fax 631 784 2201 www samsontech com...