Samson POWER AMPLIFERS SZ1120 Owner'S Manual Download Page 11

7

Designing an Installation Plan

Using A Constant Voltage Speaker System - continued

The same principle is applied in constant voltage 
audio systems where a transformer is connected to the 
amplifier’s output to step up the voltage while lowering 
the output current, which allows you to use long runs of 
lower gauge wire to connect to a series of speakers with 
step down transformers. For further cost savings, the 70 
volt standard was adopted in the US since UL requires 
the use of conduit on line over 100 volts peak. In addition 
to 70 volt operation, the SZ Series amplifiers can also 
operate 100 volt systems which is a standard in Europe. 
Commercial sound systems, like those installed in schools, 
office buildings and restaurants commonly make use of 
constant voltage distributed sound systems when a large 
number of ceiling speakers are used to cover several 
different sound zones.
Today, there are a large number of installation speakers 
available from various manufacturers that include 
onboard transformers for constant voltage systems. 
Many of these models, like the Samson dB300i, include 
selectable power taps on the transformer allowing you 
to distribute the power efficiently through the number 
of installed speakers and also adjust some speakers 
to different output levels(see diagram below). The SZ 
Series amplifiers have built in transformers that step 
up the output voltage and reduce the current allowing 
you to connect to a series of speakers with step down 
transformers over long cable runs.
A simple way to think about using constant voltage is to 
divide the total watts available by the number of speakers 
you want to use. You could also add up the speaker's step 
up transformer wattage to equal 100 watts or less.  For 
example, if you want to use ten ceiling speakers on one 
SZ1120 amplifier, use a ceiling speaker with a 12-watt 
transformer tap (120 watts divided by 10 speakers equals 
12-watts per speaker).

Typical ceiling speaker with onboard transformer and six 
power taps. These power taps also control volume level for 
sound balancing. 

Another example is connecting four of the Samson 
dB300i with the transformers wired for 25 watts to 
each channel of the SZ Series amplifier.

Following the wiring diagram on the rear of the 
dB300i, connect the ground to Common, the Hot lead 
to 70 volt input, and finally, run a jumper from 8 ohms 
to the 25 watt connection as shown in the diagram 
below.  

Set up each of the dB300i the same way so that the 
four connected speakers equal 100 watts.

The dB300i's rear panel is configured for 70 volt, 25 watt 
operation.

Now connect the four speakers to each of the 
SZ1120's output as shown in the diagram below.  

Zone 2

Summary of Contents for POWER AMPLIFERS SZ1120

Page 1: ...POWER POWER POWER SZ1120 SZ1240 SZ1360 POWER AMPLIFERS SZ SERIES...

Page 2: ...NG TYPE PLUG POLARIZED PLUG HAS TWO BLADES WITH ONE WIDER THAN THE OTHER GROUNDING TYPE PLUG HAS TWO BLADES AND A THIRD GROUNDING PRONG 4HE WIDE BLADE OR THE THIRD PRONG ARE PROVIDED FOR YOUR SAFETY F...

Page 3: ...or objects have fallen into the unit the unit has been exposed to rain or moisture does not operate normally or has been dropped PRECAUCION Para reducir el riesgo de incendios o descargas no permita q...

Page 4: ...h com Table of Contents Introduction 1 SZ Series Features 2 SZ Series Layout Front Panel 3 SZ Series Layout Rear Panel 4 Designing an Installation Plan 5 Setting Up and Using Your SZ Series 8 The SZ S...

Page 5: ...teel chassis 19 inch rack mount design and convenient carry handles facilitating easy installation in any rack Optimized for commercial installations including schools houses of worship office buildin...

Page 6: ...d frequency response of 70Hz to 18kHz guarantee ultra clean sound quality LED signal indicators continuously display power output levels and allow you to correct for overloading clipping conditions Fo...

Page 7: ...ED to fade slowly when the amp is powered off When lit no signal is provided to any connected speakers thus muting them and preventing any thump from occurring For a complete description of the condit...

Page 8: ...iring and interconnection instructions 5 LEVEL ADJUST This control knob provides input level adjustment from 12dB to 0dB 6 HPF HIGH PASS FILTER Selectable High Pass or low cut filter at 400Hz used whe...

Page 9: ...owered You can connect line level signals on all four input channels so signals from TAPE CD DVD or Karaoke players Audio Video TV monitors Radio Tuners DJ mixers or any other line level device can be...

Page 10: ...no liability for any installation Designing an Installation Plan Now take some time to consider where you need to have sound in your particular installation After you have decided where you need to cr...

Page 11: ...so adjust some speakers to different output levels see diagram below The SZ Series amplifiers have built in transformers that step up the output voltage and reduce the current allowing you to connect...

Page 12: ...placed it can be used free standing or mounted in a standard 19 rack requiring only two rack spaces When installed make sure that both the front and rear panels are unobstructed and that there is good...

Page 13: ...ent conditions This occurs whenever the signal being output from the SZ Series rises to a level above 20 THD Total Harmonic Distortion Shorted speaker cables This will occur if due to faulty wiring th...

Page 14: ...4 ohm 8 ohm and 70 Volt operation SZ Series Connections 8 Ohm Operation One 8 Ohm speaker per amplifer 8 Ohm 8 Ohm 4 Ohm 4 Ohm 4 Ohm Operation Two 8 Ohm speakers per amplifer 70 Volt Operation Four sp...

Page 15: ...and music The first two SZ amps are connected to four wall mounted speakers in each of the Dining Rooms with their transformers set to a 25 watt tap The third SZ amp powers two speakers in the outside...

Page 16: ...tion Signal Ground 1 3 2 2 3 1 Hot Cold Female XLR Male XLR Hot 2 Cold 3 Common 1 Common Hot Cold Hot 2 Cold 3 Common 1 Common Solder Points End View End View Solder Points 1 2 3 2 1 3 SZ Series Input...

Page 17: ...LECTRICAL SHOCK DO NOT HOLD OR TOUCH THE COMMON AND 70 OR 100 VOLT WIRE CONNECTION WHILE OPERATING THE AMPLIFIER 25 Volt Wiring Guide Follow the guidelines below to select the appropriate size wire ba...

Page 18: ...T H D at 1 2 rated output 1kHz Less than 1 0 Cooling Variable speed fan Operating Temperature Humidity 0 40 C at 95 non condensing Power Consumptions at full power SZ1120 185W SZ1240 361W SZ1360 525W...

Page 19: ...15 Block Diagram...

Page 20: ...Samson Technologies Corp 45 Gilpin Avenue Hauppauge New York 11788 8816 Phone 1 800 3 SAMSON 1 800 372 6766 Fax 631 784 2201 www samsontech com...