Introduction

Thank you for purchasing the PG2200 or PG 3800 power amplifier from Samson! We know you don’t like reading 

owners manuals, but you’ve just purchased one of the finest sound reinforcement power amplifiers around, and we 

want to tell you about it!  So, before you plug in, we’d like to suggest you take just a few moments out to scan these 

pages. We’ll make it as painless as possible, we promise—and, who knows, you might just pick up a tip or two. The 

Samson PG Series stereo power amplifiers have been designed to a specification we call Pure Gain Amplification. 

The PG series amplifiers provide robust, clean output with low distortion and wide dynamic range, along with the 

dependability demanded by the most professional audio engineers and installers. This manual covers both the 

PG2200 and PG3800 models. The PG series convenient 2 rack-space design is compact, and yet there’s plenty of power 

available, with 2 x 280 Watts at 8Ω, 2 x 500 Watts at 4Ω and 2 x 1000 Watts at 2Ω for the PG2200 and 2 x 560 Watts at 

8Ω, 2 x 900 Watts at 4Ω and 2 x 1800 Watts at 2Ω for the PG3800. For mono applications, a Bridge mode links both 

channels of the amplifiers, thus providing even more power, with massive mono power ratings of 1000 watts at 8Ω, 

2200 watts at 4Ω for the PG2200 and 1800 watts at 8Ω, 3800 watts at 4Ω for the PG3800. Making input connections 

is simple since the PG series’ rear panel provides both balanced XLR and balanced 1/4-inch TRS connections. For the 

outputs, the PG Series amplifiers provide standard 5-way binding posts, as well as dual Speakon™ connectors.  The 

front-panel controls and displays include a large power switch with LED indicator, as well as independent left and 

right channel input level controls. To help you set the correct operating levels, the PG series amplifiers include front 

panel Signal, Peak and Protection LED indicators. The PG series amplifiers also include onboard dynamics processing 

with a selectable Low Frequency Filter at 30 Hz to help remove stage rumble and a selectable Limiter to help protect 

your speakers and help keep your signal clean. Like all serious power amplifiers, the PG Series internal electronics are 

based around a serious power-core, with over-sized toroidal transformers and large extruded heat sinks. To keep the 

PG series amplifiers running cool, their designs employ twin internal wind tunnels with forced-air cooling via two 

temperature-sensitive, variable speed fans, which greatly reduces the chance of thermal and overheating problems. 

Multi-stage protection for power-up, over-heating, over-current, short circuit, low output impedance and DC voltage, 

assures high reliability under the most demanding situations. The PG series amps are road tough with their all steel 

chassis, 19-inch rack mount design and convenient carry handles, the PG series amplifiers are ready for a life of travel, 

or at  home in a nice fixed installation. Optimized for live sound venues, houses of worship, commercial installations, 

and for driving small and medium-sized live PA systems, the PG series amplifiers will deliver reliable power from gig-

to-gig and venue-to-venue, day in and night out. 

With proper care and adequate air circulation, your PG Series amplifier will operate trouble free for many years. We rec-

ommend you record your serial number in the space provided below for future reference.

Serial number:_____________________________________

Date of purchase: ___________________________________

In these pages, you’ll find a detailed description of the many features of the PG Series power amplifier, as well as a 

guided tour through its front and rear panels, step-by-step instructions for its setup and use, and full specifications.  

You’ll also find a warranty card enclosed—please don’t forget to fill it out and mail it in so that you can receive online 

technical support and so we can send you updated information about these and other Samson products in the future. 

Also, be sure to check out our website (www.samsontech.com) for complete information about our full product line.

SPECIAL NOTE: Should your PG Series ever require servicing, a Return Authorization number (RA) is necessary.  Without 

this number, the unit will not be accepted.  If purchased in the United States, please call Samson at 1-800-372-6766 for 

a Return Authorization number prior to shipping the unit.  If purchased outside the United States, contact your local 

Samson dealer for details.  Please retain the original packing materials and, if possible, return the unit in its original 

carton and packing materials. If you purchased your Samson product outside the United States, please contact your 

local distributor for warranty information and service.

1

Summary of Contents for POWER AMPLIFERS PG2200

Page 1: ...PG3800 PG2200 POWER AMPLIFERS PG SERIES...

Page 2: ...NG TYPE PLUG POLARIZED PLUG HAS TWO BLADES WITH ONE WIDER THAN THE OTHER GROUNDING TYPE PLUG HAS TWO BLADES AND A THIRD GROUNDING PRONG 4HE WIDE BLADE OR THE THIRD PRONG ARE PROVIDED FOR YOUR SAFETY F...

Page 3: ...or objects have fallen into the unit the unit has been exposed to rain or moisture does not operate normally or has been dropped PRECAUCION Para reducir el riesgo de incendios o descargas no permita q...

Page 4: ...AMSON 1 800 372 6766 Fax 631 784 2201 www samsontech com Table of Contents PG Series Features 2 Guided Tour Front Panel 3 Guided Tour Rear Panel 4 Setting Up and Using Your PG Series 5 Setting Up and...

Page 5: ...d large extruded heat sinks To keep the PG series amplifiers running cool their designs employ twin internal wind tunnels with forced air cooling via two temperature sensitive variable speed fans whic...

Page 6: ...wanted low fre quency rumble Unique stable bipolar circuit design that continuously keeps DC output during idling at or near zero volts thus keeping idle speakers at their zero point This serves to mi...

Page 7: ...e front panel LED indicator will illuminate when the Power switch is set to the ON position 6 PROTECT LED This goes on for approximately five seconds whenever the PG Series is powered on and then turn...

Page 8: ...9 in this manual for more information about Bridge mode and pages 10 and 11 in this manual for full speaker connection instructions 5 Circuit Breaker This circuit breaker will trip if there is a faul...

Page 9: ...nel 1 input only see page 9 in this manual for more information If your mixer or crossover network has balanced outputs we recommend the use of three conductor cabling and connectors unbalanced two co...

Page 10: ...g normally you will hear an audible click at the conclusion of this brief period as the protection circuitry is deacti vated and the PG Series begins delivering signal to connected speakers at which p...

Page 11: ...Series in Bridge mode be sure to connect your loudspeaker as shown in the illustrations on page 10 and as silkscreened on the rear panel with the red terminal of the Channel 1 output connected to the...

Page 12: ...PG Series Connections SPEAKON SPEAKON SAMSON MPL2242 MMPL2242 MPL2242 2 ohm min 2 ohm min 2 ohm min 2 ohm min SAMSON MPL2242 MMPL2242 MPL2242 4 ohm min 4 ohm min 4 ohm min 4 ohm min SAMSON MPL2242 MMP...

Page 13: ...tions 2 ohm min 2 ohm min SAMSON MPL2242 MMPL2242 MPL2242 2 ohm min 2 ohm min SAMSON MPL2242 MMPL2242 MPL2242 4 ohm min 4 ohm min 4 ohm min 4 ohm min SAMSON MPL2242 MMPL2242 MPL2242 Parallel Mode two...

Page 14: ...03 0 03 S N ratio 100dB 100dB GENERAL SPECIFICATIONS PROTECTION Full short circuit open circuit thermal ultrasonic and RF protection stable into reactive or mismatched loads turn ON OFF muting CONTROL...

Page 15: ......

Page 16: ...Samson Technologies Corp 45 Gilpin Avenue Hauppauge New York 11788 8816 Phone 1 800 3 SAMSON 1 800 372 6766 Fax 631 784 2201 www samsontech com...

Reviews: