Samson POWER AMPLIFERS PG2200 Owner'S Manual Download Page 11

Bridge and Parallel Modes

The PG Series provides a rear-panel switch that allows it to be used in either Stereo, 

Bridge or Parallel mode.  When this switch is placed in the “STEREO”  (center) position, 

the PG Series functions as a true stereo amplifier, where both of the two independent 

amplifier channels (Channel 1 and Channel 2) can receive different input signals and 

produce independent output signals.  However, when the switch is placed in the 

“Bridge” (right) position, the Channel 1 inputs signal is routed to both power ampli-

fiers bridged together, producing a single output signal with mono power ratings of 

1000 watts at 8Ω and 2200 watts at 4Ω for the PG2200 and a 1800 watts at 8Ω and 

3800 watts at 4Ω for the PG3800.

The illustration on the left shows how this works.  In Bridge mode, the   polarity 

(phase) of the Channel 2 output signal is reversed relative to that of the Channel 1 out-

put signal.  Both channels then process the same input signal, with the speaker load 

connected so that power is derived from both channels.  The effective voltage swing 

seen by the load is thus doubled, so that the power output is multiplied by four.

When using the PG Series in Bridge mode, be sure to connect your  loudspeaker as 

shown in the illustrations on page 10 (and as silkscreened on the rear panel), with 

the red (+) terminal of the Channel 1 output connected to the positive input of the 

speaker and the red (+) terminal of the Channel 2 output connected to the negative 

input of the speaker.  

Do not use the black ground (-) output terminal of either channel (the speaker 

load must “float” away from the amplifier chassis).

When the rear panel switch is placed in the left “PARALLEL” position, the PG Series 

operates in a unique Parallel mode.  In this mode, connect the input signal to Channel 

1 only.  This signal is then routed to both the Channel 1 and Channel 2 power ampli-

fiers, thus producing a dual mono output, with the following power ratings: 

PG2200 2 x 280 Watts at 8Ω, 2 x 500 Watts at 4Ω and 2 x 1000 Watts at 2Ω 

PG3800 2 x 560 Watts at 8Ω, 2 x 900 Watts at 4Ω and 2 x 1800 Watts at 2Ω

See pages 10- 11 in this manual for interconnection diagrams when using the PG 

Series in Bridge or Parallel modes. 

 

WARNING: Bridge mode is to be used only when the PG Series is connected to a 

4 or 8 ohm speaker load.  Use of Bridge mode with speaker loads of less than 4 

ohms can result in severe damage to the unit due to excessive heat and current 

limiting and will void your warranty!

INPUT

CHANNEL

1(+) OUTPUT

CHANNEL

2(+) OUTPUT

Bridge Mode

7

Summary of Contents for POWER AMPLIFERS PG2200

Page 1: ...PG3800 PG2200 POWER AMPLIFERS PG SERIES...

Page 2: ...NG TYPE PLUG POLARIZED PLUG HAS TWO BLADES WITH ONE WIDER THAN THE OTHER GROUNDING TYPE PLUG HAS TWO BLADES AND A THIRD GROUNDING PRONG 4HE WIDE BLADE OR THE THIRD PRONG ARE PROVIDED FOR YOUR SAFETY F...

Page 3: ...or objects have fallen into the unit the unit has been exposed to rain or moisture does not operate normally or has been dropped PRECAUCION Para reducir el riesgo de incendios o descargas no permita q...

Page 4: ...AMSON 1 800 372 6766 Fax 631 784 2201 www samsontech com Table of Contents PG Series Features 2 Guided Tour Front Panel 3 Guided Tour Rear Panel 4 Setting Up and Using Your PG Series 5 Setting Up and...

Page 5: ...d large extruded heat sinks To keep the PG series amplifiers running cool their designs employ twin internal wind tunnels with forced air cooling via two temperature sensitive variable speed fans whic...

Page 6: ...wanted low fre quency rumble Unique stable bipolar circuit design that continuously keeps DC output during idling at or near zero volts thus keeping idle speakers at their zero point This serves to mi...

Page 7: ...e front panel LED indicator will illuminate when the Power switch is set to the ON position 6 PROTECT LED This goes on for approximately five seconds whenever the PG Series is powered on and then turn...

Page 8: ...9 in this manual for more information about Bridge mode and pages 10 and 11 in this manual for full speaker connection instructions 5 Circuit Breaker This circuit breaker will trip if there is a faul...

Page 9: ...nel 1 input only see page 9 in this manual for more information If your mixer or crossover network has balanced outputs we recommend the use of three conductor cabling and connectors unbalanced two co...

Page 10: ...g normally you will hear an audible click at the conclusion of this brief period as the protection circuitry is deacti vated and the PG Series begins delivering signal to connected speakers at which p...

Page 11: ...Series in Bridge mode be sure to connect your loudspeaker as shown in the illustrations on page 10 and as silkscreened on the rear panel with the red terminal of the Channel 1 output connected to the...

Page 12: ...PG Series Connections SPEAKON SPEAKON SAMSON MPL2242 MMPL2242 MPL2242 2 ohm min 2 ohm min 2 ohm min 2 ohm min SAMSON MPL2242 MMPL2242 MPL2242 4 ohm min 4 ohm min 4 ohm min 4 ohm min SAMSON MPL2242 MMP...

Page 13: ...tions 2 ohm min 2 ohm min SAMSON MPL2242 MMPL2242 MPL2242 2 ohm min 2 ohm min SAMSON MPL2242 MMPL2242 MPL2242 4 ohm min 4 ohm min 4 ohm min 4 ohm min SAMSON MPL2242 MMPL2242 MPL2242 Parallel Mode two...

Page 14: ...03 0 03 S N ratio 100dB 100dB GENERAL SPECIFICATIONS PROTECTION Full short circuit open circuit thermal ultrasonic and RF protection stable into reactive or mismatched loads turn ON OFF muting CONTROL...

Page 15: ......

Page 16: ...Samson Technologies Corp 45 Gilpin Avenue Hauppauge New York 11788 8816 Phone 1 800 3 SAMSON 1 800 372 6766 Fax 631 784 2201 www samsontech com...

Reviews: