15
The HP / LP Switch Has Four Clicks!
Click Menu
Function
Value
1
Lowpass high Cut Filter 2 kHz - 20 kHz
2
Lp-Order Filter Slope
0, 6, 12, 18 per Octave
3
Highpass low Cut Filter
20 Hz - 200 Hz
4
HP-Order Filter Slope
0, 6, 12, 18 per Octave
• Press the HP / LP switch so that the yellow LED is lit.
• Engage the effect by pressing the IN / OUT switch
until the yellow LED lights.
• To set the High-pass filter press the HP / LP switch
until the LCD display reads; High-pass.
• Now, use the Data Wheel to set the frequency from 20
Hz to 200 Hz.
• Press the HP / LP switch again and you will see the
menu to set filter Order, or slope. The menu will read
HP-Order.
• Use the Data Wheel to choose a slope of either 6dB,
12dB, or 18 dB.
Note:
If you want to use the Low Pass filter but not the High
Pass filter set the Low Pass filter slope to 0 dB.
• To set the Low-pass filter, press the HP / LP switch
until the LCD display reads; Low-pass.
• Now, use the Data Wheel to set the frequency from 20
Hz to 20 kHz.
• Press the HP / LP switch again and you will see the
menu to set filter Order, or slope. The menu will read
LP-Order.
• Use the Data Wheel to choose a slope of either 6dB,
12dB, or 18 dB.
Note:
If you want to use the High Pass filter but not the
LowPass filter set the High Pass filter slope to 0 dB.
Using the LIMITER for Basic Speaker Protection
In order to help you protect your speaker system, the
D3500 employs a digital Limiter. When engaged, the
digital Limiter will prevent signals from reaching outputs
levels over a desired point. The D3500’s Limiter has a vari-
able Threshold level, which is the point the limiter circuit
begins to attenuate the system. The Limiter also has a
variable Release time, which is the time the limiter circuit
takes to return the signal to the original level.
The LIMITER Switch Has Two Clicks!
Click Menu
Function
Value
1
Lim. Thr.
Threshold
0 to -100 dB
2
Lim. Rel.
Release Time
50 to 100 % (equiv
alent to 2 to 15 sec-
onds)
To operate the D3500 digital LIMITER follow these simple
steps.
• Press the LIMITER switch so that the yellow LED is lit.
• Now, engage the effect by pressing the IN / OUT
switch until the yellow LED lights.
• To access the Threshold parameter, press the LIMITER
switch until you see the menu, Lim. Th. The LIMITER
Threshold can be set from –100 dB to 0 dB.
• To access the Release parameter, press the LIMITER
switch until you see the menu, Lim. Rel. The LIMITER
Release time can be set from 50 to 100 % (equivalent
to 2 to 15 seconds).
�
�
�
�
�
�
�
�
�
�
�����
������
�����
��