EB 4747 EN
25
Mounting
5.4
Attachment according to
IEC 60534-6 (NAMUR rib)
Î
See Fig. 4.
Î
Required mounting parts and accesso
-
1.
Check the pin position of the follower pin
(2) on the lever (1). Refer to travel tables
for type of attachment. If necessary,
change the pin position (see section 5.2).
2. Screw the stop screw into the enclosure
cover and unscrew the cover.
3. Fasten the limit switch on the bracket (2).
4.
Screw the two bolts (3) to the bracket of
the stem connector, place the follower
plate (4) on top and use the screws for
fastening.
5.
Place the bracket with limit switch on the
NAMUR rib of the valve in such a man
-
ner that the follower pin (7) rests in the
slot of the follower plate (4).
6. Align the middle of the bracket to the
50 % marking on the travel indicator
scale and fasten it using its screw (1) on-
to the valve.
Summary of Contents for 4747
Page 1: ...Translation of original instructions EB 4747 EN Edition September 2022 Type 4747 Limit Switch...
Page 20: ...20 EB 4747 EN Design and principle of operation 3 7 Dimensions in mm 94 77 40 99 80 30...
Page 45: ...EB 4747 EN 45...
Page 46: ...46 EB 4747 EN...
Page 47: ...EB 4747 EN 47...
Page 48: ...48 EB 4747 EN...
Page 49: ...EB 4747 EN 49...
Page 50: ...50 EB 4747 EN...
Page 51: ...EB 4747 EN 51 Annex...
Page 52: ...52 EB 4747 EN Annex...
Page 53: ...EB 4747 EN 53...
Page 54: ...54 EB 4747 EN...
Page 55: ...EB 4747 EN 55...
Page 56: ...56 EB 4747 EN...
Page 57: ...EB 4747 EN 57...
Page 58: ...58 EB 4747 EN...
Page 59: ...EB 4747 EN 59...
Page 60: ...60 EB 4747 EN...
Page 61: ...EB 4747 EN 61...
Page 62: ...62 EB 4747 EN...
Page 63: ...EB 4747 EN 63...