Shipment and on-site transport
4 Shipment and on-site trans
-
port
The work described in this section is only to
be performed by personnel appropriately
qualified to carry out such tasks.
4.1 Accepting the delivered
goods
After receiving the shipment, proceed as fol
-
lows:
1. Check the scope of delivery. Check that
the specifications on the nameplate and
on the regulator itself match the specifi
-
cations in the delivery note. See the
'Markings on the device' section for
nameplate details.
2.
Check the shipment for transportation
damage. Report any damage to
SAMSON and the forwarding agent
(refer to delivery note).
3. Determine the weight and dimensions of
the units to be lifted and transported in
order to select the appropriate lifting
equipment and lifting accessories. Refer
to the transport documents and the 'De
-
sign and principle of operation' section.
4.2 Removing the packaging
from the regulator
The regulator is delivered as an assembled
unit.
Î
Do not open or remove the packaging
until immediately before lifting to install
the regulator into the pipeline.
Î
Leave the regulator in its transport con
-
tainer or on the pallet to transport it on
site.
Î
Do not remove the protective caps from
the inlet and outlet until immediately be
-
fore installing the valve with flanges into
the pipeline. They prevent foreign parti
-
cles from entering the valve.
Î
Dispose and recycle the packaging in ac
-
cordance with the local regulations.
4.3 Transporting and lifting the
regulator
Due to the low service weight, lifting equip
-
ment is not required to lift and transport the
regulator (e.g. to install it into the pipeline).
Î
Leave the regulator in its transport con
-
tainer or on the pallet to transport it.
Î
Observe the transport instructions.
Transport instructions
Î
Protect the regulator against external in
-
fluences (e.g. impact).
Î
Do not damage the corrosion protection
(paint, surface coatings). Repair any
damage immediately.
Î
Protect the regulator against moisture
and dirt.
Î
The permissible ambient temperature of
standard regulators is –20 to +80 °C.
Summary of Contents for 44-0 B
Page 12: ...1 8 EB 2626 1 EN Safety instructions and measures...
Page 24: ...3 10 EB 2626 1 EN Design and principle of operation...
Page 36: ...7 2 EB 2626 1 EN Operation...
Page 40: ...8 4 EB 2626 1 EN Malfunctions...
Page 50: ...11 2 EB 2626 1 EN Removal...
Page 52: ...12 2 EB 2626 1 EN Repairs...
Page 54: ...13 2 EB 2626 1 EN Disposal...
Page 56: ...14 2 EB 2626 1 EN Certificates 1...
Page 57: ...EB 2626 1 EN 14 3 Certificates...
Page 58: ...14 4 EB 2626 1 EN Certificates 2 3...
Page 62: ...15 4 EB 2626 1 EN Annex...
Page 63: ......
Page 64: ......
Page 65: ......